Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0625-01114
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/13/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/05/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0625-01114 (4697 S CAMPBELL AV TUCSON, AZ 85714) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC), 2012 Outdoor Lighting Code (OLC). https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf Outdoor Lighting Review: 1. The calculations on sheet ES2.1 do not meet the requirements of OLC 104.2.1. 104.2.1 Lumen calculation on plans. There shall be documentation on the plans to demonstrate compliance with the lumen cap per Table 401.1, and which includes the following information: 1. Each exterior luminaire type with the lumens for that type, the quantity of each type and whether the luminaire is full cut-off or unshielded. 2. The total of full cut-off and unshielded lumens for the parcel. 3. A statement of the lighting area, the size of the permitted parcel, and the maximum allowed full cutoff and unshielded lumens. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 08/08/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0625-01114 Location: 4697 S CAMPBELL AV Review Date: 8/8/2025 Site Engineering Comments: 1. Site Engineering will be unable to review and approve permit TC-COM-0625-01114 until the associated development package TD-DEV-0625-00156 is approved by all reviewers. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 08/13/2025 | Site Zoning Standard | REQUIRES RESUBMIT | FROM: Ramiro Olivarez PDSD Zoning Review Section PROJECT: TC-COM-0625-01114 4697 S CAMPBELL AV – C-2 New Commercial Build – Financial Service (2nd Review) TRANSMITTAL DATE: August 13, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Financial Service is an allowed use in the zone (UDC Table 4.8-6). Financial Services is subject to the following use specific standards C-2: 4.9.4.L.3, 4.9.13.E, and 4.9.13.P. 1. Comment: Zoning has reviewed the construction of the new commercial building plans for compliance with Development Package (DP) TD-DEV-0625-00156 and all though the plans appear to match until the DP is approved by all review agencies Zoning cannot approve this permit. If you have any questions about this transmittal, please contact Ramiro Olivarez at Ramiro.Olivarez@tucsonaz.gov |
||
| 07/23/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |