Permit Review Detail
Review Status: Requires Resubmit
Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Permit Number - TC-COM-0624-01172
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/05/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/05/2026 | External Reviewers - Stantec Express | REQUIRES RESUBMIT | January 5, 2026 1st Review Ankrom Moisan Architects Attn: Jason Jones 38 NW Davis Street Portland, Oregon 97209 Re: CAPSTONE SPEEDWAY STUDENT HOUSING SUPER, SHELL, CORE & FITOUT (DEFERRED SUBMITTALS) City of Tucson Permit Number: TC-COM-0624-01172 Stantec Project Number: 185215066 Stantec File Number: TUC-25-115 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms A-3 I-A 7,600 278 Yes Yes B 2,288 16 R-2 44,340 227 S-2 54,885 250 R-2 III-A 165,181 946 Separate Permits: Automatic fire sprinklers, fire alarm, smoke control, swimming pool, site utilities. Deferred Submittals: Pre-engineered wood trusses, exterior cladding and steel stud framing, steel stairs, glass guardrail, roof tie backs and anchorages, post-tension shop drawings, non-bearing interior stud partition walls, elevator shop drawings, storefront shop drawings. Special Inspections: Earthwork, concrete, caissons, post-tension, epoxy and expansion anchors, structural steel, high-strength bolts, field welding, masonry, wood construction, and outdoor lighting. ARCHITECTURAL COMMENTS General 1. The stair 1 and 2 shop drawings indicate on the documents that the plans are not for construction. Please resubmit stairs 1 and 2 shop drawings that are final and for construction. 2. The floor truss and roof truss calculations indicate on the documents that they are not for construction. Please resubmit floor truss calculations that are final and for construction. STRUCTURAL COMMENTS General 1. The roof trusses, floor trusses, level 1 post-tension slab, level 2 post-tension slab, and stair 2 shop drawings all include a review stamp from PK Associates but do not include a mark on the status of the review. Please revise and resubmit. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Architectural reviewed by: Trevor Bies Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 12/23/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |