Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0624-01124
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/18/2024 | Water - PDSD | APPROVED | |||
07/17/2024 | Site Engineering | NOT REQUIRED | |||
07/18/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
06/26/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | June 24, 2024 1st Review Medmar Tanque Verde Attn: Aari Ruben 8060 E. 22nd Street Tucson, Arizona 85710 Re: 5851 E. SPEEDWAY SUITE 151 TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0624-01124 Stantec Project Number: 185215066 Stantec File Number: TUC-24-063 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms M III-B 25,600 N/A Yes Yes Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: None. Special Inspections: Wood roof strengthening. ARCHITECTURAL COMMENTS General 1. Please indicate that the fire alarm system [2018 IBC Sec. 907] is to be provided as part of this project and are to be submitted as a separate permit (not a deferred submittal). 2. Note on the cover of the drawings that special inspection is required for wood roof strengthening. Also, the special inspection certification is missing a signature from the owner or legal agent. Sheet A4 1. Suite 105 exceeds the common path of egress travel distance allowed. Please revise the plan accordingly to meet this requirement. [Ref. IBC 2018 Sec. 1006.2.1] STRUCTURAL COMMENTS There are no comments. MECHANICAL COMMENTS Sheet M2 1. Please provide an energy conservation compliance report for the new mechanical system. [Ref. IECC 2018 Sec. 403] PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS Sheet E4.0 1. Keynote 3 indicated on the plans does not have a description. Please clarify. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
07/09/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0624-01124 5851 E SPEEDWAY BL Unit: 151. - C-2 Landlord Interior Remodel 103,105,141,151 ( Review) TRANSMITTAL DATE: July 9, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Mixed use is a permitted use in the zone (UDC Table 4.8-4). 1. As no marijuana use has been approved for this site remove the reference from the plan. 2. Zoning was not able to find an approved development package or site plan for the “OUTDOOR PATIO” shown on the plan. Either provided a copy of an approved development package/site plan clearly showing the outdoor patio or a development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1, must be submitted and approved prior to approval of this permit. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
07/16/2024 | Fire New Construction | REVIEW COMPLETED | |||
06/14/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |