Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0525-01042
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/20/2025 | Site Engineering Standard | APPROVED | |||
| 06/20/2025 | Site Zoning Standard | APPROVED | |||
| 06/16/2025 | Commercial Plumbing Standard | NOT REQUIRED | |||
| 06/16/2025 | Water - PDSD Standard | NOT REQUIRED | |||
| 06/20/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/16/2025 | Commercial Building Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0525-01042 ADDRESS/PARCEL: (8605 E OLD VAIL RD TUCSON, AZ 85747) Submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. Please paste the review comment individually and enter your response directly below it. Please do this for every comment. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. Should the above not followed, it may delay your approval. COMMENTS: 1. The orientation of the Office Factory Built Building does not match the Development Package. a. Please correct to match the Development Package. 2. The size of the Office Factory Built Building is shown as 8’ x 40’. a. The Development Package shows it as 14’ x 60”. b. Please coordinate and reflect the correct size. 3. Two Storage Trailers a. You submitted information drawings on the Office Factory Build Building. b. Similarly, please submit information for these two storage trailers allowing the city to verify size, electrical power if provided, air conditioning if provided, etc. c. Please specify what will be stored and the quantity/volume for hazardous materials. 4. Fence a. Please provide drawings for this fence. b. Provide drawings for gates. c. Provide drawings for man gates. d. Please coordinate with Tucson Fire Department regarding knox box. i. Please locate and identify on the drawings. 5. Portable Restroom. a. Locate and label the portable restroom on the drawings. b. The portable restroom is not identified in the Development Package. c. The agreement is good for 2025 as indicated in the contract document. i. This agreement is to exist and enforceable until this business entity is no longer in operation on this site. Please enumerate this on the contract. 6. Please submit a copy of the construction drawing approved by the State of Arizona. 7. The state will be inspecting the installation. Please submit a copy of the installation plan approval. 8. Please resubmit. If you have any questions about these comments, I can be reached at Justin.Eder@tucsonaz.gov or 520-837-4976 |
||
| 06/04/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0525-01042 (8605 E OLD VAIL RD TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. 2. Is the Conex office pre-manufactured and approved by the state or field modified for the intended use? Field modified will require an electrical floorplan showing the location of all electrical outlets and disconnects. 3. Provide a complete line diagram, NEC 110.2, 2018 IBC 107.1. 4. Provide a panel schedule, showing the circuits that are being modified, added or removed. NEC arts;300 and 408.4. 5. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. 6. Show the location of the panel on the Electrical Plan with clear working space compliance, 2017 NEC 110.26(A) 7. Provide an electrical riser diagram, 2017 NEC 230.9. Notate the grounding and bonding method, 2017 NEC 250.20(B), 250.24, 250.30(A)(4). Metallic gas lines must be bonded and not be used as the primary grounding method, 2017 NEC 250.50, 250.52(B)(1). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
| 06/16/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | 1. Demonstrate energy code compliance for the building envelope using calculations based on the current code. Reference: Sections C101.5, C103.2, C303, and C401.2, International Energy Conservation Code 2018. 2. Provide heating and cooling load calculations to justify the heating/cooling capacities of the specified HVAC units. Reference: Section C403.1.1 and C403.3.1, IECC 2018. 3. Show that the proposed HVAC equipment meets the minimum performance requirements of Section C403.3.2, IECC 2018. 4. Show the size, routing, and termination of the condensate drains. Reference: Section 307.2.1, IMC 2018 as amended by the City of Tucson. 5. Ventilation is required and must be provided whenever the space is occupied. Reference: Sections 401.2 and 401.3, IMC 2018. |
||
| 06/04/2025 | Outdoor Lighting Standard | REQUIRES RESUBMIT | Outdoor Lighting Review TC-COM-0525-01042 (8605 E OLD VAIL RD TUCSON, AZ 85747) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. Note and show compliance with outdoor lighting if any new exterior lights are being added. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/building-code/2012_outdoor_lighting_code_.pdf 2. Provide an outdoor lighting plan that meets the requirements of OLC 104.2. Show/locate the different light sources on your site plan. Number the light fixtures on your lighting fixture table and use the same number on your site plan. 3. List the Lighting Area per OLC chapter 3 and used in Table 401.1. Specify the compliance option from Table 401.1 that is being used. Total outdoor light output shall not exceed the lumen limits listed in Table 401.1. 4. Show compliance with City of Tucson Outdoor Lighting Code with an approved lighting calculation in accordance with OLC 104.2.1, 401.2. Include all exterior fixtures on the property in the calculations. List shielded and unshielded lights in the calculation. Show unshielded fixtures with a maximum of 3,000 lumens, OLC 401.4. Show lamps with a maximum of 3500K color temperature, OLC 402.1. |
||
| 06/04/2025 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 05/27/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |