Permit Number: TC-COM-0525-01025
Parcel: 13014023A

Address:
4220 E 22ND ST

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL REVISION v.1

Permit Number - TC-COM-0525-01025
Review Name: COMMERCIAL REVIEW - FULL REVISION v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/03/2026 Commercial Building Standard APPROVED Building (B) Reviewer
Andrew Bevis; abevis@safebuilt.com
Discipline Status:Approved As Is
Date Completed: 5/28/2026

Structural (S) Reviewer
Andrew Bevis; abevis@safebuilt.com
Discipline Status:Approved As Is
Date Completed: 5/28/2026
06/03/2026 Commercial Electrical Standard APPROVED Electrical (E) Reviewer
Ron Ross; rross@safebuilt.com
Discipline Status:Approved As Is
Date Completed: 5/28/2026
06/03/2026 Commercial Mechanical Standard APPROVED Mechanical (M) Reviewer
Jorge Valido; jvalido@safebuilt.com
Discipline Status:Denied
Date Completed: 6/3/2026
1.General -Revision Narrative 06 Detail Redesign dated 05/14/2026 states for Plan Sheet M001 "-Added Electrical 153
mini split unit per owner comments.", No noted revisions, dated 05/14/2026 on any of the Mini-Split schedules. - 2018
IECC Section C103.2Information on construction documents. - 2024 IBC Section [A]107.2.1Information on
Construction Documents.
06/03/2026 Commercial Plumbing Standard APPROVED Plumbing (P) Reviewer
Andrew Bevis; abevis@safebuilt.com
Discipline Status:Approved As Is
Date Completed: 5/28/2026
06/04/2026 Outdoor Lighting Standard APPROVED No changes to the previously approved outdoor lighting.
06/15/2026 Water - PDSD Standard APPROVED
06/17/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/02/2026 Site Engineering Standard REQUIRES RESUBMIT Permit Activity Number: TC-COM-0525-01025 (REV 1st Review)
Project: This project is a renovation of an existing Chrysler Dodge Ram Fiat dealership. The work includes the addition of a separate Jeep showroom and the enclosure of two existing canopies to create an interior Service Drive and New Vehicle Delivery, respectively. Interior customer-facing areas will receive a reconfigured floor plan, new finishes, and new lighting. Back-of-house updates include a new owner-provided parts storage platform in the existing parts area, and renovated tech locker rooms. The scope of work includes a new Express Service building with service, wet and dry detail bays. This includes restrooms, lockers, and breakroom for the shop staff. This building is considered as part of Unlimited Area Building described in the code analysis and is fully sprinklered. Exterior site improvements and building signage to be submitted under a separate permit. 75,895 sf is the entire existing + new building square footage, including the new express building. Site drawings are submitted under a separate permit: TD-DEV-0425-00111
Location: 4220 E 22ND ST
Review Date: 6/2/2026
Reviewer: Marco Contreras – Engineering Associate
Reviewer Contact Information: marco.contreras@tucsonaz.gov

Site Engineering Comments:
1. Upon review of issued Development Package TD-DEV-0425-00011 in conjunction with the proposed revisions submitted under Commercial Permit TC-COM-0525-01025, Site Engineering has identified discrepancies between the two plan sets. Notably, the commercial building plan set does not appear to be consistent with the approved Development Package, including but not limited to the Conex container relocation, proposed (revised) downspout locations as shown on Sheet A400. The applicant shall pursue one of the following paths to resolution:
a. Revise the Commercial Plan Set to Conform with the Approved Development Package. The commercial building plan set shall be revised to reflect what was approved under TD-DEV-0425-00011. This includes buildings footprints, dimensions, square footages, and downspout locations.
a. Revise the Development Package to Reflect the Intended Scope. If the applicant wishes to proceed with the design as shown in the commercial plan set, a revision to Development Package TD-DEV-0425-00011 must be initiated. The moved Conex container should be included in all site calculations as well as proposed new location, along with showing the downspouts on the associated grading plan sheet. Please be advised that Site Engineering will be unable to grant final approval to TC-COM-0525-01025 until the Development Package revision has been reviewed and approved by all applicable reviewers.
06/12/2026 Site Zoning Standard REQUIRES RESUBMIT PDSD TRANSMITTAL

FROM:
Bobby Parsons
Zoning Section Review

PROJECT:
TC-COM-0525-01025 - TD-DEV-0425-00111
4220 E 22nd St. Tucson, AZ 85711
Renovation of existing Chrysler Dodge Ram Fiat dealership (1st Review)

TRANSMITTAL DATE: 6/12/2026

This site is located in the C-2 zone (UDC 4.7.21). Vehicle rental and sales is a permitted use in the zone (UDC Table 4.8-4) subject to Use Specific Standard 4.9.9.G.1 & 2.

Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed.

1. Comment: As you are proposing to relocate the existing Conex container within the PAAL, a revision to the associated DP (TD-DEV-0425-00111) will be required. The DP will need to be revised to include this updated GFA as the Conex container was not accounted for in the approved DP. Site Zoning is unable to approve this revision until the associated Development Package has been revised to show the updated Conex location.
2. Comment: Additional comments may be forthcoming depending on responses to zoning review comments and plans submitted.

If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov.
06/17/2026 Fire New Construction Standard REVIEW COMPLETED
05/27/2026 PDSD Application Completeness Express REVIEW COMPLETED