Permit Review Detail
Review Status: Requires Resubmit
Review Details: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Permit Number - TC-COM-0525-01016
Review Name: BUILDING DEFERRED SUBMITTAL REVIEW v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/09/2026 | Bldg Permits - Post Review Express | REQUIRES RESUBMIT | |||
| 03/09/2026 | External Reviewers - Stantec Express | REQUIRES RESUBMIT | March 9, 2026 1st Review Lizard Rock Designs Attn: Carina Eichorst 1640 E. River Road, Suite 206 Tucson, Arizona 85718 Re: LINDA AVENUE APARTMENTS NEW BUILDING City of Tucson Permit Number: TC-COM-0525-01016 Stantec Project Number: 185215066 Stantec File Number: TUC-26-013 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms R-2 V-A 38,548 170 Yes Yes B S-2 Separate Permits: Automatic fire sprinklers and fire alarm. Deferred Submittals: Wood trusses. Special Inspections: Earthwork, concrete, epoxy and expansion anchors, and fabricated systems and elements. ARCHITECTURAL COMMENTS There are no comments. STRUCTURAL COMMENTS General 1. The truss calculations indicate 2x8 @ 16” O.C. for Stair 1 and stair 2 on the second and third floor. The structural plans indicate that these areas are intended to be trusses. This has been commented on by the engineer of record on the truss calculations. Please revise. MECHANICAL COMMENTS There are no comments. PLUMBING COMMENTS There are no comments. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
| 03/02/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |