Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0525-01005
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/30/2025 | Commercial Plumbing Standard | APPROVED | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Reason: Date Completed : 7/29/2025 9:26:50 PM |
||
| 08/07/2025 | Outdoor Lighting Standard | APPROVED | Approved with the following 'Pre-issuance' condition added: An Outdoor Lighting Special Inspections Intermediate Certificate must be submitted and reviewed prior to issuance of this permit. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate_odl.pdf |
||
| 08/14/2025 | Water - PDSD Standard | APPROVED | |||
| 08/14/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 07/30/2025 | Commercial Electrical Standard | REQUIRES RESUBMIT | Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 7/25/2025 2:37:16 PM 1. E4.3: Single Line Riser Diagram needs to provide Overcurrent protection for MDP Panel per NEC 240.4. This can be through the Disconnect switch (enclosed CB or Fused Disc.) or a Main Circuit breaker in the MDP panel. Current design has no overcurrent protection shown. Not Addressed ◦ Response: Design Complies. Please refer to sheet E4.3 Single Line Riser Diagram showing a disconnect switch on the SES. ◦ Design needs to comply with NEC 240.4 or NEC 230.71. NEC 240.4 requires overcurrent protection for service feeder. Current design shows a Non-Fused disconnect which provides no overcurrent protection. 2. E4.3: Need to provide conductor and grnd wire size for Computer panel on Single Line Riser Diagram. Addressed 3. E4.3: PV system needs to be called out as a future permit submittal or provide raceway/feeder information and equipment values if it is to be permitted with this application. Not Addressed ◦ Response: Sheet E4.3 – Revised PV system to coordinate with solar drawings (under separate permit). Feeder information for the PV system has been added. ◦ Conductors are undersized for PV CB #7 located in MDP. Reduce size of 80 amp CB or upsized #6 AWG conductors to PV system for coordinated overcurrent protection. 4. ES1.2: Need to perform a Tucson City Lumens per acre calculation as per local electrical code requirement and show compliance. Addressed on ES1.3 |
||
| 08/12/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: TC-COM-0525-01005 Location: 5651 S HOUGHTON RD Review Date: 8/12/2025 Site Engineering Comments: 1. Site Engineering will be unable to review and approve permit TC-COM-0525-01005 until the associated Development package TD-DEV-0525-00132 has been reviewed and approved. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 08/11/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Ramiro Olivarez Zoning Review Section PROJECT: TC-COM-0525-01005 141019160 – PAD-12 Zoning (2nd Review) TRANSMITTAL DATE: August 11, 2025 This site is located in PAD-12 COMMENTS: Please resubmit revised drawings and a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Comment: Final Site Zoning approval of this plan cannot occur until the development package (DP), TD-DEV-0525-00132, is approved by all review agencies. Once approved, please resubmit the building permit corrected construction plans. 2. Comment: The specific use within the building footprint is “Food Service” not “Restaurant”. 3. Comment: Additional comments may be forthcoming on the next review based on the proposed use and applicable use specific standards. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: As noted above. If you have any questions about this transmittal, please contact Ramiro Olivarez Ramiro.Olivarez@tucsonaz.gov |
||
| 07/24/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |