Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0524-01041
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/25/2024 | Site Zoning | APPROVED | |||
07/03/2024 | Water - PDSD | APPROVED | |||
06/25/2024 | Site Engineering | NOT REQUIRED | |||
07/03/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/19/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 6/18/2024 11:53:46 PM 1. (General) Please update the title blocks of all sheets to include the street address for the property not just Banner University Medical Center Tucson. 2018 IBC Sec. 107.2.1. 2. Sheet T2.0 (General Information). Update the drawing index indicates there was to be an S1.0 Additive Alternate #2 that was not included in the set. Provide the missing sheet or remove all references from the drawings. 2018 IBC Sec. 107.2.1. 3. Sheet T2.0 (General Information). Indicate under the Project Code Date the following additional information: i. Provide the square footage of the area to be renovated. ii. Indicate the Alteration Level per the classification of work as identified per chapter 6 of the 2018 International Building Code. iii. Indicate the Occupancy Classification for the area being renovated per Chapter 3 of the 2018 International Building Code. iv. Indicate the Construction Type for the building per Chapter 6 of the 2018 International Building Code. v. Indicate the existing structure has an existing automatic fire sprinkler and fire alarm system. Indicate if there are to be any work on these systems required due to the reconfiguration of the bathroom walls. 4. Sheet T2.0 (General Information). Indicate the following additional applicable codes listed under the Project Code Data: i. 2018 International Existing Building Code ii. ICC A117.1 - 2009 Accessible and Usable Buildings and Facilities (by reference). 5. Sheet G2.6 (Life Safety Plan). Provide plan for the area to be renovated that indicates the occupancy count and exit paths. The area of work shall be provided with the minimum number of exits based on the occupancy and occupant load in accordance with the 2018 IBC Sections 805.3 through 805.3.3. 2018 IEBC Sec. 805.3. The referenced Life Safety Plan from 2007 is sufficient for showing the 6th level overall, the existing fire partitions and the general layout of the exit and paths. 6. Sheet G2.6 (Life Safety Plan). Note on the drawings that that all alterations shall be done in a manner that maintains the level of fire protection 2018 IEBC Sec. 703.1 7. Sheet G2.6 (Life Safety Plan). Note on the drawings that alterations shall be done in a manner that maintains the level of protection provided for the means of egress. 2018 IEBC Sec. 704.1. 8. Sheet A8.1 (Opening Schedule and Details). Provide information on the new door hardware to be installed on the Opening Schedule for the new sliding doors, this column was left blank. 9. Sheet A9.1 (Room Finish Schedule). Indicate on the Room Finish Schedule that all interior finishes will be in accordance with 2018 IBC Sec. 803.1. |
||
06/07/2024 | Fire New Construction | REVIEW COMPLETED | |||
06/03/2024 | PDSD Application Completeness | REVIEW COMPLETED |