Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0524-00779
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/10/2024 | Water - PDSD | APPROVED | |||
| 06/10/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/23/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Denied Reason: Date Completed : 5/22/2024 6:40:36 PM 1. UPDATES: For project updates, please submit sheets with all changes clearly marked in revision clouds. Please provide a written response to each comment; updates without a clear response to all comments may not be reviewed. If you have any questions regarding the comments, you may contact me directly. Updates may result in additional comments. 2. GEOTECHNICAL REPORT: Please provide a copy of the site-specific geotechnical report for this project referenced in the structural general notes. The report should support the appropriateness of the selected foundation system for the project site. All building code references must be updated to the current code adopted by the City. [Please note that the allowable soil bearing pressure used by Specialty Engineer, Jimco Sales & Manufacturing, does not match the structural general notes on Sheet S0.1 (Refer to Dwg No CA5). Maximum allowable bearing pressure will need to be confirmed in the geotechnical report and may require revisions by Jimco.] Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/11/2024 1:20:30 AM Sheet G1.0 1. Update the sheet index so it matches the drawings that were provided in the set. 2. Include to the list of applicable codes the City of Tucson/ Pima County Outdoor Lighting Code. ◦ Site plan 3. Indicate the accessible route from the new diesel pumps to the interior of the convenience center where the new “Diesel Smart Desk” will be located. It appears that there may be an existing sidewalk on the south side of the store, but it does not appear to be connected to the new driveway. 2009 ICC A117.1 chapter 402.1. Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 5/20/2024 2:34:42 PM 1. General - If applicable provide Mechanical plans for existing building. Show all new and existing duct work. Show all new and existing A/C equipment. Show new refrigeration, If no Mechanical work is to be performed, respond with "NO Mechanical work in the scope for this job" - 2018 IBC Section [A]107.2.1Information on construction documents. - 2018 IECC Section C103.2Information on construction documents. Electrical(E) Reviewer Ron Ross rross@safebuilt.com Denied Reason: Date Completed : 5/11/2024 7:40:23 PM 1. E1.3 ELECTRICAL SITE DETAILS: Sheet is missing from set. Need to provide or confirm that it is no longer needed. 2. Comment concerning sheet E2.0 ELECTRICAL FLOOR PLAN: Keynote 8 is used, but no description provided. 3. Comment concerning sheet E2.1 ELECTRICAL FLOOR PLAN: Sheet is not shown on sheet legend. 4. Comment concerning sheet E7.1 PANEL SCHEDULES: New Panelboard (NEW) schedule is not identified/named, nor is it shown/located on drawings to show compliance with NEC 110.26. 5. Comment concerning sheet SE1.0 Keynotes are poorly aligned and could not locate Keynotes 1 and 9. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 5/21/2024 9:39:34 PM First Plumbing Review: 1). Plan sheets Tk101 & Tk506: each water hydrant needs its own shut off valve & vacuum breaker. Add an individual shut off valve & vacuum breaker at each water hydrant. -2018 IPC 606.2 & 608.16.4.2 |
||
| 06/04/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 06/03/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0524-00779 - TD-DEV-0324-00089 530 E VALENCIA RD - C-2 Multifamily (1st Review) TRANSMITTAL DATE:June 3, 2024 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). General Merchandise Sales, excluding Large Retail Establishment, is a permitted use in the zone (UDC Table 4.8-4), subject to Use Specific Standard 4.9.9.B.1. 1. COMMENT: Zoning has reviewed the building plan for compliance with TD-DEV-0324-00089 and although the plans appear to match the DP, Zoning cannot approve the building plans until the DP is approved by all review agencies. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 05/26/2024 | Fire New Construction | REVIEW COMPLETED | -All fuel related equipment requires a separate permit from TFD. Contact Inspector Silva for submittal and inspection information, 520-419-9177 jesus.silva@tucsonaz.gov 5208377094 |
||
| 05/08/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |