Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0523-01415
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/20/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 10/04/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 6/16/2023 3:44:21 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 9/28/2023 12:22:00 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Approved with Comments Reason: Date Completed : 6/4/2023 9:24:18 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Reason: Date Completed : 9/27/2023 7:19:39 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 10/3/2023 12:51:16 AM Second Plumbing Review: 1). Unresolved-Café floor sink on plan pages P2.3 , P2.5, P4.0 needs to discharge to the grease system -IPC 1003.1 **Provide letter from utility authority stating café plumbing can bypass grease system -See Tucson Plumbing code amendments** 2). Resolved-Plan page A1.1 Ice machines #181 & 182 can't be located in Laundry - Update all affected plumbing & floor plan pages. -IPC 801.2 3). OK-Washer on plan pages P2.5 & P4.0 need to discharge thru a lint interceptor -IPC 1003.6 ** Subject to Field Inspections to determine type** 4). Resolved-Floor sink beyond the walk-in production cooler on plan page P2.4 can't be located on the exterior of the bldg. - IPC 1101.3 5). Resolved-First double wye on grease system page P4.0 is in the wrong direction of flow -IPC 706.3 6).Resolved- Restrooms 116 & 117 on plan page A1.1 can't open into baking area - IPC 403.3.2, Update all affected pages **See Note 28 Food service doors** 7). Resolved-Baking oven water connections on plan page P2.2 need backflow protection -IPC 608.3 8). Resolved-TMV needs to be shown at Lavs on plan pageP2.2 -IPC 419.5 9). Resolved-Plan page A1.4 notes 8 & 9 show new roof drains & Gutter, plans need to include sizing calculations - IPC 1106.1, 1106.2, 1106.3, 1106 10). Resolved-Plan page A1.4 needs to include downspout sizing information. -IPC 1106.3 11). Resolved-plan page A1.4 needs to include Roof drain & overflow detail. 12). Resolved-Plan page P0.1 fixture schedule needs to include roof drain & overflow assembly info - IPC 1102.6 13). Resolved-Plumbing plans need to include roof drain & routing illustrations - IPC 106.3.1 |
||
| 10/20/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0523-01415 825 S. Park Ave. - I-1 Food & Beverage Wholesaling & Commercial Storage (2nd Review) TRANSMITTAL DATE: October 20, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in I-1 zone (UDC 4.7.29), Food & Beverage Wholesaling & Commercial Storage are allowed use in the zone (UDC Table 4.8-5), subject to Use Specific Standards 4.9.10.a & 4.9.13.Q. 1. This comment was not addressed. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0223-00140 and there appears to be a discrepancy between the two plans. The building plans are proposing a “Café” or food service. Food service was not a use provided on the DP. As the DP has been approved the DP will need to revised to show the food service use and all calculation revised. Until a DP addressing the food service use is approved Zoning cannot approve this building plan. 2. This comment was not addressed. There is also a staircase called out under Keynote 9 on sheet A1.1 that is not shown on the DP and appears to encroach into a required loading space. If you have any questions about this transmittal, please contact, Zone1.desk@tucsonaz.gov |
||
| 09/27/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |