Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0426-00619
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/14/2026 | Commercial Electrical Standard | APPROVED | |||
| 05/20/2026 | Commercial Plumbing Standard | APPROVED | |||
| 05/21/2026 | Site Zoning Standard | APPROVED | |||
| 05/20/2026 | Water - PDSD Standard | APPROVED | |||
| 05/14/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 05/01/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 05/21/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/18/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please revise Sheet 2-A-504. It appears the microwave and its controls will be located outside the obstructed side reach ranges permitted by ICC A117.1-2017 Sections 308 (Reach Ranges) and 309 (Operable Parts). Please revise the plans to reduce the reach range or demonstrate how the microwave placement complies with the accessibility requirements. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 05/20/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | The City of Tucson has adopted the 2024 IMC as the approved method for calculating ventilation requirements for occupancies other than ambulatory care facilities and I-2 occupancies. The ventilation of spaces within these healthcare occupancies for which no functionally equivalent spaces exist in ASHRAE 170/ASHE or NFPA 99, shall be based on Section 403, IMC 2024. Reference: Sections 401.2 and 407.2, IMC 2024 as amended by the City of Tucson. If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 05/21/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 04/30/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |