Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0425-00680
Parcel: 138160140

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0425-00680
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
04/28/2025 Commercial Mechanical APPROVED
04/25/2025 Site Zoning APPROVED
04/17/2025 Fire New Construction NOT REQUIRED
04/17/2025 Outdoor Lighting NOT REQUIRED No changes to the outdoor lighting .
04/28/2025 Bldg Permits - Post Review Express PENDING ASSIGNMENT
04/24/2025 Commercial Building REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
1. Please provide the following information: R106.1
General Project information to include a detailed description of the work to be performed, location map and square footage.
2. The currently adopted codes to be enforced on this project. For example, 2018 International Residential Code (IRC)
3. Please provide a sheet index.
4. Provide an architectural site plan to identify the location of the building the permit is being used for.
5. Please provide the fenestration U-factor, and SHGC IRC N1102.1.2 and the STC rating of the new windows. R106.1
6. Please provide the architectural drawings and details for the construction of the new exterior stairway. R106.1
Please contact me if you have any questions about these comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
email mark.masek@tucsonaz.gov
04/17/2025 Commercial Electrical REQUIRES RESUBMIT Commercial Electrical Review TC-COM-0425-00680 (6744 S NOGALES HY TUCSON, AZ 85756)
Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received.
Code reference, 2018 International Residential Code (IRC), 2018 International Building Code (IBC), 2017 National Electrical Code (NEC).

1. Arc-fault protection. Provide Arc-fault protection per NEC 210.12(A). All listed branch circuits that supply 120V, 15- and 20-amp outlets shall be AFCI protected.

All 120-volt, single-phase, 15- and 20-ampere branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms or areas shall be protected by any of the means described in 210.12(A)(1) through (6):

2. Provide GFCI protection in laundry area per NEC 210.8(A)(10).
3. Show all wiring methods in detail for all branch circuit wiring and feeders. Conductor type and conduit size/type. Note wet use requirements. NEC arts;300 and 408.4.


Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov
04/11/2025 PDSD Application Completeness Express REVIEW COMPLETED