Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0424-00763
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/08/2024 | Site Engineering | NOT REQUIRED | |||
07/16/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/15/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. Please provide evidence on a site lighting plans that this parcels exterior lighting fully complies with the 2012 City of Tucson Outdoor Lighting Code as required for 'Change of Use' applications, OLC section 102.5.. 1. Provide site lighting plans with the following information on the plans; (a) Provide a complete luminaire schedule. (b) Full compliance with sections 104.2.1(1), (2), (3). 2 See table 401.1, Include parcel size, lighting area and option, and indicate this information in the lighting site plan. 3 402.1 (light source color temperature requirements, 3500K), shielding requirements, etc . 4 Provide calculations for total lumens allowed and total lumens proposed per acre for Full Cut Off and Unshielded per table 401.1.Must include existing to remain lighting. 5 Indicate whether or not a special inspection is required per sec. 104.2.2, and 106.2. 6 Specify any exceptions used. 7 Provide Curfew lighting controls If applicable Per section 403. 8 Provide complete compliance with the 2018 IECC for the interior and exterior lighting where applicable. Do not confuse the Outdoor Lighting Code with the IECC. Ref; 2017 NEC, 2012 Tucson/Pima County Outdoor Lighting Code (OLC), 2018 IBC sec 107.2.1. 2018 IECC. |
||
07/16/2024 | Commercial Mechanical | REQUIRES RESUBMIT | Provide additional information regarding the proposed materials and processes that led to assigning an S-1 (Moderate Hazard Storage) occupancy. Detail the manufacturing processes that will be conducted at this facility. Reference: Section 107.2.1, IBC 2018. | ||
07/15/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter to address each of the comments indicating how the Building Review comments were addressed. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. 1. The plans indicate mixing and packaging taking place in this facility. Please amend plans to indicate if there is any manufacturing, extraction, cultivation, infusion, etc associated with this facility. Additionally, amend plans to indicate if any chemical, solvent, pesticides, etc., are used in this process that pose a hazardous threat. Please review the IBC Hazardous Material Quantities Tables and provide a list for this facility if required. Please note that additional information such as chemical storage, fire separation from storage area may be required. 2. Please amend the floor plan to show the manufacturing equipment layout and where the egress paths are to be located. IBC 107.2.1 Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
07/16/2024 | Site Zoning | REQUIRES RESUBMIT | FROM: Loran Shamis PDSD Zoning Review Section PROJECT: TC-COM-0424-00763 Marijuana Dispensary Off Site Manufacturing Location Tenant Improvement (1st Review) 2175 E VALENCIA RD UNIT 185 TRANSMITTAL DATE: July 16, 2024 DUE DATE: July 15, 2024 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. COMMENT: Per UDC 4.9.9.E.2.k, an odor mitigation plan shall be submitted demonstrating compliance with odor control requirements - this can be a narrative explaining the odor mitigation devices and techniques incorporated in the marijuana facility to ensure that odors are mitigated. As such, this may be done through an exhaust air filtration system with odor control that prevents internal odor control that prevents internal odors from being emitted externally. Zoning will review this requirement with a Commercial Mechanical reviewer from the Building Safety Division. 2. COMMENT: As you are proposing a change of use with a more intensive parking ratio than the previously approved use, provide a site plan for the entire site with the parking calculation per UDC 7.4.4-1. Marijuana Dispensary Off-site Manufacturing location requires 1 parking space per 300 square feet of gross floor area. Warehouse use is considered a Commercial Storage use which requires 1 space per 5,000 gross floor area and Professional and Administrative Office requires 1 space per 300 square feet of gross floor area. Reference permit number T18CM04115. 3. COMMENT: Include the approved Marijuana Use Authorization letter on the plan set. If you have any questions about this transmittal, Contact Loran Shamis at 520-837-2242 or by email Loran.Shamis@tucsonaz.gov |
||
07/12/2024 | Fire New Construction | REVIEW COMPLETED | |||
06/10/2024 | PDSD Application Completeness | REVIEW COMPLETED |