Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0424-00746
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/06/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/06/2024 | External Reviewers - Stantec | REQUIRES RESUBMIT | June 4, 2024 2nd Review Intertech Architectural Interiors, Inc. Attn: Brittany Thrasher Hammond 6089 East Grant Road Tucson, Arizona 85716 Re: DECIBEL COFFEE WORKS TENANT IMPROVEMENT City of Tucson Permit Number: TC-COM-0424-00746 Stantec Project Number: 185215066 Stantec File Number: TUC-24-042 Plan review for the above referenced project has been completed. This letter reflects comments to be addressed. PLEASE send all response to comments back to the City through the permit portal! Responses sent directly to Stantec will be ignored. Also, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please cloud and delta all changes and provide a letter with a written response to each of the comments indicating the action taken. The scope of this review covers the architectural, structural, plumbing, mechanical, and electrical designs as they relate to the codes adopted by the jurisdiction. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions, and concerns before permit approval. Occupancy Group Construction Type Area (Square feet) Occupant Load Automatic Fire Sprinklers Fire Alarms B V-B 1,143 25 No No Separate Permits: Signage. Deferred Submittals: None. Special Inspections: None. ARCHITECTURAL COMMENTS General 1. Addressed. 2. Addressed. 3. The plan-set indicates the installation of a new mechanical unit on the roof weighing 675lbs. This unit appears to be in a different area of the roof than the original unit. Please provide a structural analysis that indicates the proposed units can be placed at the locations indicated with/without additional reinforcement. [Ref. IBC 2018 Sec. 1604.4] {This comment is also included in the ‘Structural Comments’ section.} Still Required: I understand that the existing roof will be modified to support the new mechanical unit under a separate permit per the response narrative. Please indicate on sheet A9 that the structural modifications required to support the new mechanical will be done under a separate permit. Sheet G1 1. Addressed. Sheet G2 1. Addressed. Sheet G3 1. Addressed. 2. Addressed. STRUCTURAL COMMENTS General 1. The plan-set indicates the installation of a new mechanical unit on the roof weighing 675lbs. This unit appears to be in a different area of the roof than the original unit. Please provide a structural analysis that indicates the proposed units can be placed at the locations indicated with/without additional reinforcement. [Ref. IBC 2018 Sec. 1604.4] Still Required: I understand that the existing roof will be modified to support the new mechanical unit under a separate permit per the response narrative. Please indicate on sheet A9 that the structural modifications required to support the new mechanical will be done under a separate permit. MECHANICAL COMMENTS General 1. Addressed. PLUMBING COMMENTS Sheet P1.0 1. Addressed. ELECTRICAL COMMENTS There are no comments. Should you have any questions regarding the plan review comments, please contact the plan reviewer listed for the appropriate discipline. Plans reviewed by: Trevor Bies, Senior Plan Reviewer 602-338-9922 trevor.bies@stantec.com |
||
05/29/2024 | PDSD Application Completeness | REVIEW COMPLETED |