Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0424-00577
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/06/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT 1 & TC-COM-0242-00585/UNITS 2 & 3 | ||
| 05/10/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 5/10/2024 9:27:15 AM The structural review is approved. Subject to the field inspector's approval. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 5/10/2024 9:25:02 AM 1. Unresolved - Sheet C1.1: Include the entire fire separation UL design for the separation wall or walls between units B and C. other sheets show two walls as part of the assembly. Provide the details for the membrane and through penetrations of the separation wall. (2018 IBC section R302.1, R302.4) Penetration details of the fire rated walls were not provided. 2. Resolved - Sheets C1.1, A1.0.A, A1.0.B: Include the fire rated exterior wall assembly design for the walls with only a one-foot fire separation distance between the two buildings. Roof projections less than 2ft to the imaginary line between the buildings are prohibited. Please revise all affected sheets. (2018 IBC section R302.1, Table R302.1(1)) 3. Resolved - Sheet C1.1: Include the lists of deferred submittals and special inspections. 2018 IRC section R106) 4. Resolved - Sheet A1.0.A: The laundry room is labeled as a kitchen. Please revise all affected sheets. (2018 IRC section R106) 5. Unresolved - Sheets A1.0.A, A1.0.B, A1.1.A, A1.1.B: Specify the windows in hazardous locations that are safety glazed. (2018 IRC section R308.4) In bedroom #4 in the single dwelling unit and all bedrooms in the duplex window 1D is not identified as being safety glazed. 6. Unresolved - Sheets A1.1.A, A1.1.B: Include the U-Factors of the windows and doors. Show the window clear openings meeting the egress requirements of the 2018 IRC section R310. (2018 IECC section R402) Not revised. 7. Resolved - Sheets A3.0.A, A3.0.B: Include the wall and ceiling insulation R-Values showing compliance with the 2018 IECC section R402. Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 5/10/2024 9:26:01 AM 1. Resolved - Manual J and S calculation reports: Provide the reports for each unit, label which unit the reports are for, and include the equipment details corresponding with the calculation results. (2015 IECC section R403.7) 2. Unresolved - Sheets M1.01, M1.02: Detail the bathroom exhaust fans vent to the exterior. (2018 M1505.2) Details not included. 3. Unresolved - Sheets M1.01, M1.02: Show the location of the dryer exhaust vents and their distances from openings. (2018 IRC section M1502) The dryer vent detail added to sheet M0.01 shows a mesh screen over the vent termination. Section M1502.3 prohibits screens on the duct termination. 4. Resolved - Sheets M1.01, M1.02: Show the walkway and platform for the HVAC equipment in the attics. Include the drawings showing the drain pans and condensate drain piping. (2018 IRC section M1305.1.2) Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 5/10/2024 9:25:34 AM 1. Resolved - Sheets C1.1, E2.02, E3.02: Include the electric vehicle charging station on the panel schedules, plans, and calculations. (2018 IRC section R106) 2. Unresolved – Sheets E1.03, E2.01 (One-Line Diagram): Show the correct voltage for the electrical service as detailed in the panel schedules. Show the locations of all electrical equipment, rating of the meter, service entrance conductors, and proper grounding electrode conductors for both buildings. (2018 IRC section R106) The service and separate building grounding electrodes are not shown on the one-line diagram. The 500Amp main disconnect, meters, and service locations are not shown on the plans. The grounding details are not legible. 3. Resolved - Sheet E2.02: Include the site panel schedule and calculations. (2018 IRC section R106) 4. Resolved - Sheets E3.01, E3.02: Show the closet light details and distance to the storage spaces. (2017 NEC sections 410.2, 410.16) 5. Unresolved - Sheets E3.01, E3.02, E4.01, E4.02: Show the locations of all electrical service equipment. (2018 IRC section R106) The 500Amp main disconnect, meters, and service locations are not shown on the plans. 6. Resolved - Sheet E4.01: Missing receptacles on the counter above the dishwasher, within 6ft of the start of the wall in the laundry room, and bedroom #4. (2017 NEC section 210.52) 7. Unresolved - Sheet E4.02: Missing receptacles on the dining room wall next to the door in both units, within 6ft of the door in the living rooms in both units, and for the refrigerator. (2017 NEC section 210.52) Still missing the receptacles within 6ft of the family room doors. 8. Resolved - Sheet E4.02: The exterior receptacles are not identified as being GFCI protected. (2017 NEC section 210.8) Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 5/10/2024 9:26:52 AM The plumbing review is approved. Subject to the field inspector's approval. |
||
| 06/04/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 06/03/2024 | Site Zoning | REQUIRES RESUBMIT | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT 1 & TC-COM-0242-00585/UNITS 2 & 3 ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0424-00577 & TC-COM-0242-00585 - TD-DEV-0324-00066 526 N WESTMORELAND AV. Units A, B & C – R-2 Multifamily (2nd Review) TRANSMITTAL: June 3, 2024 This site is located in the R-2 zone (UDC 4.7.9). Multifamily is a permitted use in this zone (Table 4.8-2), subject to Use Specific Standards 4.9.7.B.6, .9, & .10. 1. Unit Development Package, TD-DEV-0324-00066, is approved by all review agencies Zoning cannot approve these building plans. 2. This comment was not addressed. Perimeter yard setbacks are based on a wall height measurement from design grade to the highest point of the exterior wall UDC Article 6.4.5.B & Figure 6.4.5-A. Where the highest point of the wall meets the eave of the roof. As dimensions were not provided from design grade to the highest point of the wall Zoning cannot determine setback requirements. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 06/06/2024 | Water - PDSD | REQUIRES RESUBMIT | MASTER SET OF PLANS ON TC-COM-0424-00577/UNIT 1 & TC-COM-0242-00585/UNITS 2 & 3 1. The site plan shows one utility water meter serving three sub-meters. Verify the need to install a reduced pressure backflow prevention assembly immediately downstream of the utility meter with Tucson Water. Reference: Chapter XXVII, Article V, Section 27-72, the Tucson Code, https://www.tucsonaz.gov/files/sharedassets/public/city-services/tucson-water/water-quality/documents/backflow-ordinance.pdf [Initial comment: Provide a site plan showing the location of the water meter and the route of the water service to the building. Specify the material of construction for the water service pipe. Reference: Sections 107.2.1 and 107.2.6, IBC 2018. ] 2. The site plan shows one utility water meter serving three sub-meters. Provide the total water demand to be served by the utility meter, the size of the utility water meter, and the size of the water service pipe connecting the utility meter with the three sub-meters. The maximum water velocity for PVC pipe is 8 Feet per second. [Initial comment: Provide calculations for the water demand served by each water meter and showing how the water supply piping has been sized. Verify that the pipe sizes will not result in water velocities greater than those recommended by the pipe manufacturer (e.g. limit the water velocity to less than 8 FPS for copper, PEX, or CPVC piping). Reference: Sections 604.1 and 604.3, IPC 2018.]. |
||
| 05/07/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |