Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0423-01148
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/03/2023 | External Reviewers - SAFEBuilt | APPROVED | Activity Number: TC-COM-0423-01148 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 6/14/2023 10:14:02 AM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 6/12/2023 3:54:02 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/9/2023 11:45:02 PM . Provide appliance duty classification for hood 3 sheet H5.1 (IMC2018,507.2.1) Complied 2. You are exhausting 2095 cfm through hood 1 but only bringing in 1,446 cfm through the perforated supply plenum, you must bring in approximately the same amount of air that you exhaust this is the same for all 3 hoods sheet H5.1 (IMC208,508.1) Complied 3. Make note on schedule that the kitchen exhaust for the hoods shall be interlocked with the make up air unit on sheet H5.1 (IMC 2018,508.1) Complied 4. Both walk in coolers condensing units shall be on schedule with all pertinent information including the amount and type of refrigerant along with the model and serial #'s. votages, amps, etc. (IMC2018,106.3.1) Complied Approved/subject to field approval Electrical(E) Reviewer Matthew Payette mpayette@safebuilt.com Approved Reason: Date Completed : 5/20/2023 10:15:44 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 7/2/2023 10:53:34 PM Third Plumbing Review:** OK Subject To Field Inspections 1).OK 2). OK 3). OK 4). OK 5). OK-Detail #7 on plan page P3.0 illustrates the water softener discharging to a drain, no drain is shown in that area on plan pages P1.U, P1.1 & P2.0. plan pages need to correlate - IPC 106.3.1 ** Subject To Field Inspections 6). OK |
||
07/12/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/12/2023 | Site Engineering | REQUIRES RESUBMIT | Waiting on approval for TD-DEV-0423-00212 Scott Haseman scott.haseman@tucsonaz.gov |
||
07/06/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0423-01148 203 S; Wilmot Rd. – C-1 Food Service (3rd Review) TRANSMITTAL DATE: July 06, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.20). Food Service is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. 1. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0423-00212 and although it appears that the plans match until the DP is approved by all review agencies Zoning cannot approve this building permit. 2. This comment was not addressed correctly. The DP sheets submitted in the building set are not the stamped approved DP sheets. There is no PDSD Approval stamp on any of the DP sheets. The development package sheets provided in the building plan set either need to be the stamped approved set, marked for reference only or removed from the set. If you elect to mark for reference only do not mark sheet C1.3 for reference only as it is reviewed for compliance by the plumbing review. If you elect to remove the plans from the set, do not remove sheet C1.3 as it is reviewed for compliance by the plumbing review. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
06/29/2023 | PDSD Application Completeness | REVIEW COMPLETED |