Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0423-01148
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
06/21/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
06/15/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0423-01148 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 6/14/2023 10:14:02 AM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 6/12/2023 3:54:02 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 6/9/2023 11:45:02 PM Approved/subject to field approval Electrical(E) Reviewer (from previous submittal TUC9250001.050823) Matthew Payette mpayette@safebuilt.com Approved Reason: Date Completed : 5/20/2023 10:15:44 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 6/14/2023 8:47:16 PM Second Plumbing Review: 1). SAME-Roofs A & C on plan pages A1.2 & P1.1 need secondary drains -IPC 1106.5. 1108 2). OK 3). OK 4). OK 5). SAME-Detail #7 on plan page P3.0 illustrates the water softener discharging to a drain, no drain is shown in that area on plan pages P1.U, P1.1 & P2.0. plan pages need to correlate - IPC 106.3.1 6). OK |
||
06/21/2023 | Site Engineering | REQUIRES RESUBMIT | See Zoning Comment | ||
06/13/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: PDSD Zoning Review Section PROJECT: TC-COM-0423-01148 203 S; Wilmot Rd. – C-1 Food Service (2nd Review) TRANSMITTAL DATE: June 13, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-1 zone (UDC 4.7.20). Food Service is a permitted use in this zone (Table 4.8-4), subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O. 1. Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-0423-00212 and although it appears that the plans match until the DP is approved by all review agencies Zoning cannot approve this building permit. 2. The development package sheets provided in the building plan set either need to be the stamped approved set, marked for reference only or removed from the set. If you elect to mark for reference only do not mark sheet C1.3 for reference only as it is reviewed for compliance by the plumbing review. If you elect to remove the plans from the set, do not remove sheet C1.3 as it is reviewed for compliance by the plumbing review. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
06/08/2023 | PDSD Application Completeness | REVIEW COMPLETED |