Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: TC-COM-0423-00982
Parcel: 13213104B

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0423-00982
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
07/20/2023 Site Zoning APPROVED
07/21/2023 Bldg Permits - Post Review PENDING ASSIGNMENT
07/21/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Daljit Benipal
dbenipal@safebuilt.com
Conditionally Approved
Date Completed : 7/20/2023 2:11:47 PM
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall
not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.


Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Denied
Reason:
Date Completed : 7/17/2023 10:41:39 AM
1. Sheet AI2.0: The west stair is required to have a fire resistance rating of 1 hour. However, the wall types provided for the shaft are not indicated as having a rating. Provide the listed assemblies chosen for these rating along with all necessary listing drawings and details. NOT COMPLIED.
Note: Wall type P2 is being used for the stair shaft walls. However, in the wall schedule, this wall type is not indicated as a rated assembly. The chosen listen assembly number has not been provided. Provide the listed assembly similar
to wall type P4.
1. Sheet AI2.0: The doors on the west stair are not rated properly. Provide properly rated doors in accordance with Table 716.1(2). NOT COMPLIED
Note: Door 133A that is located on the first floor of the west stair shaft is not rated properly. The door schedule has not been updated for this door. Provide a properly rated door assembly in accordance with Table 716.1(2).
1. Sheet AI2.1: The west stair is required to have a fire resistance rating of 1 hour. However, the wall types provided for the shaft are not indicated as having a rating. Provide the listed assemblies chosen for these rating along with all
necessary listing drawings and details.
Note: Wall type P2 is being used for the stair shaft walls. However, in the wall schedule, this wall type is not indicated as a rated assembly. The chosen listen assembly number has not been provided. Provide the listed assembly similar
to wall type P4.



Mechanical(M) Reviewer
Neil Samaan
nsamaan@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 4/17/2023 9:11:13 PM
Approved/subject to field approval

Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 7/16/2023 11:05:30 AM
ELECTRICAL REVIEW
By: Ron Ross PE
E5.0 ONE LINE DIAGRAM, SES AND FEEDER SCHEDULE: Need to provide correct Panel size for 1LD2 on Riser for IFC set.


Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Denied
Reason:
Date Completed : 7/14/2023 7:21:21 PM
Second Plumbing Review :
1). OK
2). SAME- Plan Page P5.0 shows the existing grease interceptor is a hydromechanical type, Per Tucson amendments a hydromechanical type can't be used for a dishwasher & or more than 4 items.** Email from Utility authority not attached as per response**
07/14/2023 PDSD Application Completeness REVIEW COMPLETED