Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0423-00982
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
07/20/2023 | Site Zoning | APPROVED | |||
07/21/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
07/21/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Date Completed : 7/20/2023 2:11:47 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 7/17/2023 10:41:39 AM 1. Sheet AI2.0: The west stair is required to have a fire resistance rating of 1 hour. However, the wall types provided for the shaft are not indicated as having a rating. Provide the listed assemblies chosen for these rating along with all necessary listing drawings and details. NOT COMPLIED. Note: Wall type P2 is being used for the stair shaft walls. However, in the wall schedule, this wall type is not indicated as a rated assembly. The chosen listen assembly number has not been provided. Provide the listed assembly similar to wall type P4. 1. Sheet AI2.0: The doors on the west stair are not rated properly. Provide properly rated doors in accordance with Table 716.1(2). NOT COMPLIED Note: Door 133A that is located on the first floor of the west stair shaft is not rated properly. The door schedule has not been updated for this door. Provide a properly rated door assembly in accordance with Table 716.1(2). 1. Sheet AI2.1: The west stair is required to have a fire resistance rating of 1 hour. However, the wall types provided for the shaft are not indicated as having a rating. Provide the listed assemblies chosen for these rating along with all necessary listing drawings and details. Note: Wall type P2 is being used for the stair shaft walls. However, in the wall schedule, this wall type is not indicated as a rated assembly. The chosen listen assembly number has not been provided. Provide the listed assembly similar to wall type P4. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 4/17/2023 9:11:13 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 7/16/2023 11:05:30 AM ELECTRICAL REVIEW By: Ron Ross PE E5.0 ONE LINE DIAGRAM, SES AND FEEDER SCHEDULE: Need to provide correct Panel size for 1LD2 on Riser for IFC set. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 7/14/2023 7:21:21 PM Second Plumbing Review : 1). OK 2). SAME- Plan Page P5.0 shows the existing grease interceptor is a hydromechanical type, Per Tucson amendments a hydromechanical type can't be used for a dishwasher & or more than 4 items.** Email from Utility authority not attached as per response** |
||
07/14/2023 | PDSD Application Completeness | REVIEW COMPLETED |