Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0423-00958
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/20/2023 | Site Engineering | APPROVED | |||
| 07/18/2023 | Site Zoning | APPROVED | |||
| 08/07/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 08/07/2023 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. The electrical plan review comments were not completely addressed or the response was not detailed enough to satisfy the review comment. 1 Response to Electrical review comment #1; The Photometric Analysis shows the new under canopy luminaires Color Temperature rated at 4000K. This is in violation of the 2012 City of Tucson Outdoor Lighting Code (OLC) section 402.1, (3500K max). To verify OLC compliance, provide the information required on the site lighting plans, per section 104.2 (Plan/Permit Submittal Requirements), and Lumen calculations per 104.2.1, 104.2.3, OLC. Provide Luminaires manufacturers cut sheet with all specifications highlighted or encircled. Be advised, Under Canopy luminaires that provide full cut-off shielding by the manufacturer, and lamp color temperature output of 3500K or less is exempt from the lumen calculations requirement per exception 104.2.1. 2 Response to Electrical review comment #2; Provide a note on the lighting plan sheet ‘E11’ addressing the exception NEC art 225.32 exception #1 as stated in the response letter, for not requiring the canopy lighting disconnect per NEC art 225.31-32. 3 Response to electrical review comment #3; The electrical line diagrams do not clearly show the PV line side tap (Interconnection) in the close proximity on the Utility Service conductor terminations. (a) Unless the holes in the busbars are marked with the word “Tap” adjacent to the holes, verify by the manufacturer of the 400-amp switchboard in writing signed by a qualifying party of the manufacturer, that the proposed PV Line side Tap at the exact specified location on this equipment (provide serial #) bus utilizing specified hardware, mechanical lugs, or other equipment, will not compromise the performance or listing of the switchboard. (b) Provide a copy of the switchboard manufacturers listing instructions showing that the equipment specified (by serial #) is listed to accommodate a PV Line side interconnection at the bus location specified, NEC 110.3(B). (c) Otherwise provide for an NRTL agency to perform a field evaluation and recertify the listing of the equipment after the PV Line Side Interconnection is performed, in order to maintain the listing and integrity of the electrical switchboard, NEC 110.3(C) Ref; 2018 IBC section 107.2.1, 2017 NEC, 2012 City of Tucson Outdoor Lighting Code. |
||
| 07/17/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |