Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0325-00501
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/29/2025 | Commercial Building Standard | APPROVED | Structural(S) Reviewer Madeline Nelson mnelson@safebuilt.com Approved Reason: Date Completed : 9/25/2025 9:06:46 AM Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Approved Reason: Date Completed : 9/23/2025 3:47:59 PM |
||
| 10/07/2025 | Site Engineering Standard | APPROVED | |||
| 10/16/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 09/29/2025 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Denied Reason: Date Completed : 9/24/2025 4:27:34 PM 1. (UNRESOLVED) - General - Provide Heat Load Calculations - 2018 IECC Section C403.1.1 Calculation of heating and cooling loads. i. Heat load Summary submitted for review shows 29 tons / Total coil load 347.7 MBH. It also shows Sensible Coil Load 347.7 MBH. Is there no Latent Load? ▪ Design load on plan sheet M5.0 shows 751.4 MBH (659.6 Sensible 91.8 MBH Latent). Design is twice the amount shown on Heat Load Calculations. Confirm Heat load calculations and design. - 2018 IECC - C403.3.1 Equipment sizing (Mandatory). - 2018 IECC Section C103.2Information on construction documents. - 2018 IBC Section [A]107.2.1Information on construction documents. |
||
| 09/29/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 9/28/2025 8:16:16 PM SECOND PLUMBING REVIEW: COMMENT 2 REMAINS RESOLVED--1). General: Address building plan review comment 2. Bldg comment 2 could affect fixture count. -2018 IPC 403.1 UNRESOLVED-2). Plan Page A0.70: Incorrect fixture count & plumbing code listed. Fixture counts need to derive from -2018 IPC 403.1 which equate to 4 male & 4 female toilets and 3 Female lavatories & 3 male lavatories . RESOLVED-3). Plan Page A0.10: Missing a complete sheet index. Update sheet index to correlate with all the plan sheets provided-2018 IPC 106.3.1 RESOLVED-4). Plan page P4.0: Missing enlarged sanitary & water details that correlate to each floor level. Add enlarged sanitary & water details that correlate to each floor level- 2018 IPC 106.3.1 RESOLVED-5). Plan Page P2.4: Missing GPM loads next to each set of Roof drains. Add GPM loads next to each set of Roof drains. -2018 IPC 1106.2 RESOLVED-5). Plan Page P6.0 Water riser diagram: Missing riser continuation that illustrates all floor levels. Add riser continuation that illustrates all floor levels. -2018 IPC 106.3.1 RESOLVED-6). Plan Page P6.1 Sanitary riser diagram: Missing riser continuation that illustrates all floor levels. Add riser continuation that illustrates all floor levels. -2018 IPC 106.3.1 RESOLVED-7). Plan page P4.0: Missing correct fixture identifier for P5 service sink and missing water heater location. Add correct fixture identifier for P5 service sink and show water heater location. -2018 IPC 106.3.1 |
||
| 10/16/2025 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Krista Hansen Planning & Development Services Department – Zoning Review Section PROJECT: TC-COM-0325-00501 - TD-DEV-1224-00333 980 W IRVINGTON RD – C-1 Personal Storage (2nd Review) TRANSMITTAL DATE: 10/16/2025 This site is located in the C-2 zone (UDC 4.7.21). Personal Storage is an approved use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.10.C.3 & .6. 01. COMMENT: Zoning has reviewed the building plans for compliance with Development Package (DP) TD-DEV-1224-00333 and although it appears that the building plans match the DP, until the DP is approved by all review agencies, Zoning cannot approve this building permit. For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov |
||
| 09/30/2025 | Water - PDSD Standard | REQUIRES RESUBMIT | 1. Comment not addressed. [Initial comment: Provide a site plan showing the location of the water meter, reduced pressure backflow assembly and the route of the water service to the building. Specify the material of construction for the water service pipe. Reference: Section 107.2.1, IBC 2018.] 2. Comment not addressed. [Initial comment: Provide the size of the water meter serving the building, the size of the backflow preventer associated with the water meter, and the total water demand served by the water meter. Reference: Section 107.2.1, IBC 2018.] |
||
| 09/22/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |