Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0324-00462
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/25/2024 | Water - PDSD | APPROVED | |||
| 06/25/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/03/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Nicholas Baptiste njnobaptiste@safebuilt.com Denied Reason: Date Completed : 5/29/2024 10:25:48 PM 1. General / Information Required. Provide components and cladding design wind pressures for roof, wall, and parapet surfaces. (UNRESOLVED) ◦ Provide components and cladding diagram per ASCE 7-16 Figure 30.3 applicable to structure to accompany wind pressures provided including dimension ("a" or "h") for zone widths. ◦ Per ASCE 7-16 30.2.2 "The design pressure for C&C of buildings shall not be lass than a net pressure of 16 psf". Revise pressures lower than minimum value. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 5/29/2024 7:46:06 AM 4. Unresolved - Sheet A9.10: The openings in guards of 4” or more are prohibited. Include the landing guard details. (2018 IBC section 1015.4) Details #6, #7, and #9 still show guard openings of 4” which would allow a 4” sphere to pass through the opening. 1015.4 exception 1 requires less than 4” openings up to 36” above the floor and less than 4 -3/8” openings from 36” to 42” above the finished floor. A 6” sphere shall not be able to pass through the triangle openings created by the tread, riser, and bottom rail. The landing guard details at the top of the stairwell were still not included. Mechanical(M) Reviewer Jorge Valido jvalido@safebuilt.com Approved Date Completed : 3/29/2024 11:49:52 PM Electrical(E) Reviewer Ron Ross rross@safebuilt.com Approved Date Completed : 5/28/2024 7:00:31 PM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Approved Date Completed : 6/2/2024 4:06:46 PM |
||
| 06/25/2024 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
| 06/18/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0324-00462 - TD-DEV-0923-00393 8800 E SPEEDWAY BL – C-2 Personal Storage (1st Review) TRANSMITTAL: June 18, 2024 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the C-2 zone (UDC 4.7.21). Personal Storage is an allowed use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.10.C.3 & .6. 1. The plans appear to match the Development Package. However, zoning cannot approve until it is approved. nicholas.martell@tucsonaz.gov |
||
| 05/28/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |