Permit Number: TC-COM-0324-00462
Parcel: 13335002U

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0324-00462
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
06/25/2024 Water - PDSD APPROVED
06/25/2024 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/03/2024 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Nicholas Baptiste
njnobaptiste@safebuilt.com
Denied Reason:
Date Completed : 5/29/2024 10:25:48 PM
1. General / Information Required. Provide components and cladding design wind pressures for roof, wall, and parapet
surfaces. (UNRESOLVED)
◦ Provide components and cladding diagram per ASCE 7-16 Figure 30.3 applicable to structure to accompany
wind pressures provided including dimension ("a" or "h") for zone widths.
◦ Per ASCE 7-16 30.2.2 "The design pressure for C&C of buildings shall not be lass than a net pressure of 16
psf". Revise pressures lower than minimum value.


Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied Reason:
Date Completed : 5/29/2024 7:46:06 AM

4. Unresolved - Sheet A9.10: The openings in guards of 4” or more are prohibited. Include the landing guard details.
(2018 IBC section 1015.4) Details #6, #7, and #9 still show guard openings of 4” which would allow a 4” sphere to
pass through the opening. 1015.4 exception 1 requires less than 4” openings up to 36” above the floor and less than 4
-3/8” openings from 36” to 42” above the finished floor. A 6” sphere shall not be able to pass through the triangle
openings created by the tread, riser, and bottom rail. The landing guard details at the top of the stairwell were still not
included.



Mechanical(M) Reviewer
Jorge Valido
jvalido@safebuilt.com
Approved
Date Completed : 3/29/2024 11:49:52 PM



Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Approved
Date Completed : 5/28/2024 7:00:31 PM



Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Approved
Date Completed : 6/2/2024 4:06:46 PM
06/25/2024 Site Engineering REQUIRES RESUBMIT See zoning comment
06/18/2024 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0324-00462 - TD-DEV-0923-00393
8800 E SPEEDWAY BL – C-2
Personal Storage (1st Review)

TRANSMITTAL: June 18, 2024

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

This site is located in the C-2 zone (UDC 4.7.21). Personal Storage is an allowed use in the zone (UDC Table 4.8-4), subject to Use Specific Standards 4.9.10.C.3 & .6.

1. The plans appear to match the Development Package. However, zoning cannot approve until it is approved.

nicholas.martell@tucsonaz.gov
05/28/2024 PDSD Application Completeness Express REVIEW COMPLETED