Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0323-00866
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/30/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
05/30/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0323-00866 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 5/29/2023 11:48:14 PM Building(B) Reviewer Janet Matz jmatz@safebuilt.com Denied Reason: Date Completed : 5/29/2023 11:47:58 PM Update the egress plan on sheet A.1, it is still indicating the 62 occupants for the front exit. It is understood that the new dining room occupancy count will be 49. Mechanical(M) Reviewer (from previous submittal TUC9217001.032723) Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 4/11/2023 3:34:50 AM Electrical(E) Reviewer (from previous submittal TUC9217001.032723) Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 4/11/2023 3:34:38 AM Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 5/28/2023 7:48:05 AM Second Plumbing Review: 1). SAME- Ice machine #17 on plan pages P1.1 P3.1 can't discharge to grease system -IPC 1003.2 **Response to response narrative: Per Tucson Amendments Pima Utility Authority could allow certain items not be allowed to discharge thru the grease interceptor. an Ice Machine & AC condensate would never contain grease laden waste. Tucson amendments begin it's IPC Chapter 10 revisions with code section 1003.3. Non-revised Code section 1003.2 states **Waste that do not require treatment shall not discharge thru an interceptor or separator.** Extreme cold continuous discharge to a grease system could solidify the grease waste & cause stoppages. 2). SAME- AC & Cooler/freezer Condensate on plan page P1.1 can't discharge to grease system -IPC 1003.2 **Response to response narrative: Per Tucson Amendments Pima Utility Authority could allow certain items not be allowed to discharge thru the grease interceptor. an Ice Machine & AC condensate would never contain grease laden waste. Tucson amendments begin it's IPC Chapter 10 revisions with code section 1003.3. Non-revised Code section 1003.2 states **Waste that do not require treatment shall not discharge thru an interceptor or separator.** Extreme cold continuous discharge to a grease system could solidify the grease waste & cause stoppages. 3). OK 4). SAME-Add Sizing table used to plan page P1.3 or P3.1 -IFGC 402.4 ** Which specific table from 402.4 was used -IFGC 402.4(#)? 5). OK 6). OK 7). OK -Gas hot food serving Counter on plan page P1.3 needs to be beneath a type 2 hood - IFGC 503.2.1, IMC 507.3 ** Per comment response documentation provided City of Tucson doesn't require an appliance of this type to be beneath a Hood** OK Subject to Field Inspections 8). OK- Per manufacturer specs the Duke Hot food serving counter has drains, no floor sink is shown in the vicinity of this appliance on plan pages P1.1 & P3.1? -IPC 106.3.1, 802.1.1 Per comment response waste receptor not required by manufacture.OK Subject to Field Inspections |
||
05/25/2023 | Fire New Construction | REVIEW COMPLETED | |||
05/15/2023 | PDSD Application Completeness | REVIEW COMPLETED |