Permit Review Detail
Review Status: Approved
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0323-00864
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Approved
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/31/2023 | External Reviewers - SAFEBuilt | APPROVED | Activity Number: TC-COM-0323-00864 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer Daljit Benipal dbenipal@safebuilt.com Conditionally Approved Reason: Date Completed : 5/30/2023 5:22:57 PM NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. Building(B) Reviewer Janet Matz jmatz@safebuilt.com Approved Reason: Date Completed : 4/10/2023 11:21:36 PM Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 3/31/2023 10:37:16 PM Approved/subject to field approval Electrical(E) Reviewer Ron Ross rross@safebuilt.com Conditinally Approved Reason: Date Completed : 4/10/2023 6:25:29 PM Electrical Review By: Ron Ross PE ED001 ELECTRICAL DEMOLITION PLAN - SOUTHEAST CORNER: Keynote 3 or symbol for floor box is wrong per symbol legend on E000. Could not locate Keynote 11, but one Keynote #12 is possibly misnumbered. ED002 ELECTRICAL DEMOLITION PLAN - SOUTHWEST CORNER: Keynote 3 or symbol for floor box is wrong per symbol legend on E000. ED004 DEMO LIGHTING PLAN - SOUTHWEST CORNER: Could not locate Keynote #5. E101 POWER PLAN - SOUTHEAST CORNER: Could not locate Keynote #7. E102 POWER PLAN - SOUTHWEST CORNER: Could not locate Keynote #13. E600 PANEL SCHEDULES: 400-amp Panels DPA and DPB are not in agreement with 200-amp panels shown on E400. Coordinate, either design is code compliant. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Conditionally Approved Reason: Date Completed : 4/8/2023 12:34:50 PM First Plumbing Review: OK Subject To Field Inspections & Manufacture Specs |
||
| 05/26/2023 | Site Zoning | APPROVED | |||
| 05/31/2023 | Bldg Permits - Post Review Express | REVIEW COMPLETED | |||
| 05/25/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |