Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0226-00239
Parcel: 12217264D

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0226-00239
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/11/2026 Commercial Electrical Standard APPROVED
03/16/2026 Commercial Mechanical Standard APPROVED
03/16/2026 Site Zoning Standard APPROVED
03/16/2026 Water - PDSD Standard APPROVED
03/11/2026 Outdoor Lighting Standard NOT REQUIRED No modifications to the outdoor lighting.
02/26/2026 Site Engineering Standard NOT REQUIRED
03/17/2026 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/17/2026 Commercial Building Standard REQUIRES RESUBMIT Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed.
Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov
1. Please amend the interior elevations of the bathrooms to provide the mounting and positioning dimensions for bathroom fixtures and accessories. IBC 107.2.1 and 2017 ICC A117.1 Chapter 6
2. Please amend the plans to provide to show the required clear floor space, turning space and the approach, either forward or parallel in the bathrooms and breakroom/café. IBC 107.2.1 and 2017 ICC A117.1 Chapter 3 and 4.
3. IEBC 306.7 requires that accessibility be provided to the altered spaces. Where the existing path of travel elements, which entails a primary entrance, a primary path of travel, sanitary facilities serving the area, a drinking fountain, and signs. If these items are in full compliance with the current code, provide a statement indicating this on the cover sheet of the drawings. Otherwise, accessibility upgrades shall be required in accordance with IEBC.306.7. 1. If the cost of providing or upgrading the items above to be accessible is disproportionate to the cost of construction (exceeds 20% of the cost of construction not including accessibility upgrades), please provide information to verify construction costs.
4. Please indicate how the carpet tiles meet the requirements of IBC Section 804. Please provide the classification in accordance with ASTM E648 or NFPA 253

Please contact me if you have any questions about the above comments.
Mark Masek
Plans Examiner – Building Safety
Planning and Development Services | City of Tucson
main 520.837.4994
03/16/2026 Commercial Plumbing Standard REQUIRES RESUBMIT 1. Verify that the specified sensor faucet for the restroom lavatories has an automatic time-out so that it will dispense a maximum of 0.25 gallons per metering cycle (e.g., 30 seconds at 0.5 GPM). Verify that the cycle will operate for at least 10 seconds for accessibility. Reference: Section 604.4, IPC 2018 and Section 606.4, ICC/ANSI A117.1-17.
2. Provide tempered water for the lavatories and public hand-washing sinks in restrooms with a device conforming to ASSE 1070. Reference: Section 419.5, IPC 2024.
If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov.
03/17/2026 Fire New Construction Standard REVIEW COMPLETED
02/23/2026 PDSD Application Completeness Express REVIEW COMPLETED