Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - LIMITED v.1
Permit Number - TC-COM-0225-00251
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/25/2025 | Commercial Building | APPROVED | |||
02/24/2025 | Site Zoning | APPROVED | |||
02/24/2025 | Commercial Mechanical | NOT REQUIRED | |||
02/24/2025 | Commercial Plumbing | NOT REQUIRED | |||
02/24/2025 | Water - PDSD | NOT REQUIRED | |||
02/25/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
02/11/2025 | Commercial Electrical | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0225-00251 (3602 N ORACLE RD TUCSON, AZ 85705) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2018 2018 International Building Code (IBC), 2017 National Electrical Code (NEC). 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. 2. Provide a complete electrical plan-set showing all proposed electrical work. 3. Should include but not be limited to: a. Provide a complete line diagram, NEC 110.2, 2018 IBC 107.1. b. Provide electrical load calculations, for the Main Service Panel, Per NEC 220.40. c. Show the location of the panel on the Electrical Plan with clear working space compliance, 2017 NEC 110.26(A). d. Provide a panel schedule showing the circuits that are being modified and added. e. Show all wiring methods in detail for all branch circuit wiring along with branch circuit and breaker panel designations and correlate with the panel schedules. NEC arts;300 and 408.4. f. Show compliance with NEC 501 and 514. Highlight the appropriate Hazardous zones and areas on the electrical plans. 4. Additional comments may be required with the submittal of electrical plans. Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov |
||
02/10/2025 | Fire New Construction | REVIEW COMPLETED | The propose project requires a separate permit and review. Please contact Jesus.silva@tucsonaz.gov for special hazards permit. |
||
02/08/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |