Permit Number: TC-COM-0224-00316
Parcel: 117022420

Address:
941 N 4TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - LIMITED v.1

Permit Number - TC-COM-0224-00316
Review Name: COMMERCIAL REVIEW - LIMITED v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2024 Commercial Building APPROVED
03/13/2024 Commercial Electrical APPROVED
03/18/2024 Water - PDSD APPROVED
03/18/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
03/18/2024 Commercial Mechanical REQUIRES RESUBMIT Footnote g, Table 403.3.1.1, IMC 2018, calls for public restrooms to be mechanically exhausted. Show how this will be provided. Reference: Section 403.2.1 (4), IMC 2018.
03/18/2024 Commercial Plumbing REQUIRES RESUBMIT Provide cleanouts at the junctions of the building drains and the building sewer. Reference: Section 708.1.3, IPC 2018.
03/07/2024 Historic REQUIRES RESUBMIT The property is a contributing resource to the West University Historic Preservation Zone and requires review and approval. Please provide documents noted under Full Review in the Historic & Special Districts informational handout (https://www.tucsonaz.gov/files/sharedassets/public/v/3/pdsd/documents/submission-documents/special_districts_application_instructions_7.18.23.pdf) and submit under the Historic sub-record. Questions? Jodie.Brown@tucsonaz.gov
03/07/2024 Site Engineering REQUIRES RESUBMIT See zoning comments
03/05/2024 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: TC-COM-0224-00316
941 N 4TH AV. – HR-2
Remodel existing restroom (1st Review)

TRANSMITTAL DATE:‎ March 5, 2024

COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

COMMENTS: the following comments are relative to an application for Historic Review (UDC 5.8.8). This site is located in the HR-2 zone (UDC 4.7.9). Parks and Recreation is an allowed use in the zone (UDC Table 4.8-2), subject to Use Specific Standards 4.9.13.B & C.

1. Until approved by Historic Zoning cannot approve this plan. Historic Review is required. Please submit a special districts application as a sub-record of this permit. The submittal requirements and instructions can be found below. Please contact Jodie Brown (jodie.brown@tucsonaz.gov) or Michael Taku (michael.taku@tucsonaz.gov) for any questions. Zoning can not approve until the historic review has been approved. https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/special_districts_application_instructions-1.pdf

2. Zoning cannot approve the building plans until Development Package (DP) TD-DEV-0224-00028 is approved by all review agencies.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
02/26/2024 Fire New Construction REVIEW COMPLETED
02/26/2024 PDSD Application Completeness REVIEW COMPLETED