Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0224-00294
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 06/04/2024 | Commercial Plumbing | APPROVED | |||
| 05/31/2024 | Site Engineering | APPROVED | |||
| 05/24/2024 | Site Zoning | APPROVED | |||
| 06/07/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 06/07/2024 | Commercial Structural | REQUIRES RESUBMIT | Detached Storage Building Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Please amend plans to show an imaginary lot line to indicate where the Fire Separation Distances (FSD) are to be measured. IBC 705.3 2. Please amend plans to show compliance with IBC Table 602. For example, a 1 -hour fire-resistance rating is required for exterior walls with less than 5 feet of fire separation distance. 3. Please amend plans to show compliance with IBC Table 705.8 maximum area of exterior wall openings based on fire separation distance and degree of opening protection. Mark Masek Plans Examiner Mark.masek@tucsonaz.gov 520-837-4994 |
||
| 05/03/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |