Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0223-00654
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/30/2023 | Site Zoning | APPROVED | |||
03/30/2023 | Site Engineering | NOT REQUIRED | |||
04/03/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/27/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0223-00654 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. BUILDING REVIEW COMMENTS: Denied 1. Sheet G003: The plan provided on the indicated egress sheet is not an egress plan. Provide detailed egress plans that show the new proposed layout. 2. Sheet G003: No code analysis has been provided. Provide a Building Code Data Legend on the Title Sheet. Include the following code information for each building proposed: ◦ Occupancy Classification(s) ◦ For Mixed Occupancy Buildings, state whether the “non-separated” or “separated” option was chosen from Sections 508.3 / 508.4. ◦ Description of Use ◦ Type of Construction ◦ Sprinklers: ◦ Stories ◦ Height ◦ Floor Area (both the the existing and affected area) ◦ Occupant Load (UPDATED) 3. Multiple Sheets: The door schedules provided on each phased sheet do not match the doors on that particular phase. Provide update door schedule for each individual phase. MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E101 PHASE 01 ELECTRICAL PLANS LIMITED SCOPE: Could not locate Keynote #1. E102 PHASE 02 ELECTRICAL PLANS LIMITED SCOPE: Could not locate Keynote #1. E103 PHASE 03 ELECTRICAL PLANS LIMITED SCOPE: Could not locate Keynote #1. E104 PHASE 04 ELECTRICAL PLANS LIMITED SCOPE: Could not locate Keynote #1. E105 PHASE 05 ELECTRICAL PLANS LIMITED SCOPE: Could not locate Keynote #1. Keynote #2 last two words ‘AN Downer’ should be corrected. Comment applies to other sheets too. E108 PHASE 08 ELECTRICAL PLANS CONSTRUCTION: Could not locate Keynote #1. E109 PHASE 09 ELECTRICAL PLANS CONSTRUCTION: Could not locate Keynote #1. E114 PHASE 14 ELECTRICAL PLANS LIMITED SCOPE: May need a comment about removing power from office cubicles. PLUMBING REVIEW COMMENTS: N/A If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
04/03/2023 | Fire New Construction | REVIEW COMPLETED | |||
03/09/2023 | PDSD Application Completeness | REVIEW COMPLETED |