Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0223-00641
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/22/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 05/22/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: TC-COM-0223-00641 GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. Structural(S) Reviewer (from previous submittal TUC9180001.030323) Daljit Benipal dbenipal@safebuilt.com Denied Reason: Date Completed : 3/9/2023 3:59:01 PM 1. Provide Structural Calculations for the building at the Foundations per Section 1601.1 of International Building Code 2018. The enercalc calculations provided are for Footing F7 only. Provide complete set covering F1 thru F7. 2. Provide Wind Load Calculations showing loadings at the Foundations for the Prefabricated Building per Section 1609 of International Building Code 2018. 3. Provide Seismic Calculations showing loadings at the Foundations for the Prefabricated Building per Section 1613 of International Building Code 2018. 4. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018. 5. Provide Geotechnical Report for the proposed building per International Building Code 2018, Section 1803.1. Submit a response letter addressing these correction items and provide bubbles on the revisions to the drawings. Building(B) Reviewer Andrew Bevis abevis@safebuilt.com Denied Reason: Date Completed : 5/9/2023 11:49:49 AM 1. The updated drawings referenced in the response narrative have not been provided. Please provide updated drawings for review. Mechanical(M) Reviewer Neil Samaan nsamaan@safebuilt.com Conditionally Approved Reason: Date Completed : 4/30/2023 10:51:25 PM Approved/subject to field approval Electrical(E) Reviewer (from previous submittal TUC9180001.030323) Ron Ross rross@safebuilt.com Conditionally Approved Reason: Date Completed : 3/16/2023 9:34:05 AM Electrical Review By: Ron Ross PE E2.0 First Floor Lighting Plan: Could not locate Keynote 4. Plumbing(P) Reviewer Perry Hendershott phendershott@safebuilt.com Denied Reason: Date Completed : 5/3/2023 11:15:19 PM Second Plumbing Review: **Updated plan pages stated in response narrative Not Sent** 1). SAME-AD1 needs to be vented on plan page P2.0 -IPC 901.2.1 2). SAME-what is preventing AD1 on plan page P2.0 from receiving storm water? -IPC 1101.3 ( Plan Page A5.0 shows exterior grade at same level & this area isn't clear if it is under roof) 3). SAME-Provide civil plan for continuation of sewer and water as stated on plan pages P1.0 & P2.0 -IPC 106.3.1 4). SAME-Each Hose bib in truck parking area needs a shut off valve on plan page P1.0 -IPC 606.2 |
||
| 05/01/2023 | Site Engineering | REQUIRES RESUBMIT | The permit cannot be approved until its associated development package, TD-DEV-0223-00138, has been approved. Lianne Evans lianne.evans@tucsonaz.gov |
||
| 05/02/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: TC-COM-0223-00641 3381 E WESTCO PL Zoning I-1 TRANSMITTAL DATE:May 2, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: Zoning has reviewed the building plan for compliance with TD-DEV-0223-00138 and although it appears that the building plans match the DP Zoning cannot approve the building plans until the DP is approved. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 04/20/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |