Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: TC-COM-0223-00641
Parcel: 140418630

Address:
3381 E WESTCO PL

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.1

Permit Number - TC-COM-0223-00641
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
03/17/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
03/16/2023 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Activity Number: TC-COM-0223-00641

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.


STRUCTURAL REVIEW COMMENTS:
Denied
1. Provide Structural Calculations for the building at the Foundations per Section 1601.1 of International Building Code 2018. The enercalc calculations provided are for Footing F7 only. Provide complete set covering F1 thru F7.
2. Provide Wind Load Calculations showing loadings at the Foundations for the Prefabricated Building per Section 1609 of International Building Code 2018.
3. Provide Seismic Calculations showing loadings at the Foundations for the Prefabricated Building per Section 1613 of International Building Code 2018.
4. All Calculations shall be sealed and signed by Professional Engineer registered with State of Arizona per Section 107.1 of International Building Code 2018.
5. Provide Geotechnical Report for the proposed building per International Building Code 2018, Section 1803.1.


BUILDING REVIEW COMMENTS:
Denied
1. No architectural site plan has been provided. Provide an architectural site plan.
2. Sheet A1.1: The occupants loads on the cover Sheet and this sheet do not match. Provide matching occupant load calculations.
3. Sheet A1.1: Provide the location of all proposed furniture on the egress plans.
4. Sheet A1.1: Provide a narrative of the used of this office building. There is a tire and parts storage area. Provide the cubic feet of tire storage to ensure proper occupancy classification.
5. Provide a typical wall schedule.


MECHANICAL REVIEW COMMENTS:
Denied
1. Provide ventilation to storage rooms 003 & 004 sheet M1.0 (IMC2018,403.3.1.1.1)


ELECTRICAL REVIEW COMMENTS
Condtiaionally Approved
E2.0 First Floor Lighting Plan: Could not locate Keynote 4


PLUMBING REVIEW COMMENTS:
Denied
First Plumbing Review:
1). AD1 needs to be vented on plan page P2.0 -IPC 901.2.1
2). what is preventing AD1 on plan page P2.0 from receiving storm water? -IPC 1101.3 ( Plan Page A5.0 shows exterior grade at same level & this area isn't clear if it is under roof)
3). Provide civil plan for continuation of sewer and water as stated on plan pages P1.0 & P2.0 -IPC 106.3.1
4). Each Hose bib in truck parking are needs a shut off valve on plan page P1.0 -IPC 606.2


If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov
03/17/2023 Site Engineering REQUIRES RESUBMIT The permit cannot be approved until its associated development package, TD-DEV-0223-00138, has been approved.
03/16/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: PDSD Zoning Review

PROJECT:
TC-COM-0223-00641
3381 E Westco Pl. – I-1Addition of 22'x28' Concrete Pad for Airgas Capabilities (1st Review)

TRANSMITTAL: March 6, 2023
This site is located in I-1 zone (UDC 4.7.29).

1. As the associated Development Package, TD-DEV-0223-00138, has not completed its first review Zoning is not able to compare the two plans and will review on the next submittal. Zoning cannot approve the building plans until the DP is approved.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
03/16/2023 Fire New Construction REVIEW COMPLETED
03/01/2023 PDSD Application Completeness Express REVIEW COMPLETED