Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0126-00138
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/12/2026 | Commercial Building Standard | APPROVED | |||
| 02/03/2026 | Commercial Electrical Standard | APPROVED | |||
| 02/18/2026 | Site Zoning Standard | APPROVED | |||
| 02/10/2026 | Water - PDSD Standard | APPROVED | |||
| 02/17/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 02/18/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/10/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00138 ADDRESS/PARCEL: 6246 E PIMA ST Unit:UNIT 180 TUCSON, AZ 85712 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Provide information on the sequence of operation for the restroom exhaust fan to show that all of the air supplied to the restroom will be exhausted. Reference: Section 403.2.1 (4), IMC 2024. |
||
| 02/10/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00138 ADDRESS/PARCEL: 6246 E PIMA ST Unit:UNIT 180 TUCSON, AZ 85712 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Please show that the distance from the hot water source (i.e., the recirculating loop) to the hot water termination for the public lavatory complies with the requirements of Section C404.5, IECC 2024. 2. The metering faucet shall dispense a maximum of 0.25 gallons per metering cycle. Verify that the faucet cycle will last for at least 10-seconds for accessibility. Reference: Section 412.13, IPC 2024, as amended by the City of Tucson and Section 606.4, ICC/ANSI A117.1-09. |
||
| 02/17/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 02/03/2026 | PDSD Application Completeness Express | REVIEW COMPLETED | limited scope TI timeline |