| 11/19/2026 | Commercial Plumbing Standard | APPROVED | |||
| 11/19/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 11/04/2026 | Site Engineering Standard | REQUIRES RESUBMIT | Permit Activity Number: TC-COM-0126-00127 (3rd Review) Project: Rising Star Church - New Ground Up Location: 2800 E 36TH ST Review Date: 11/04/2026 Reviewer: John Mounsey – Engineering Associate Reviewer Contact Information: john.mounsey@tucsonaz.gov Site Engineering Comments: 1. Site Engineering has completed its review of the submitted plan set and cross-referenced it against the associated development package. However, as you acknowledged, Site Engineering is unable to grant final approval for Commercial Permit: TC-COM-0126-00127 until the associated revision to Development Package TD-DEV-0226-00031 has received full approval and has been issued. Please resubmit for final approval once the development package has been approved and issued by all applicable reviewers. For final approval - Ensure that all building plans match in regard to footprint, proposed height and square footage, as well as show that the downspout and structure drainage systems match with what is shown in the development package plan set. |
||
| 11/17/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Jeffrey W. Cassidy, Planner I Planning & Development Services Department – Current Zoning Review Section, Commercial PROJECT: TC-COM-0126-00127 – Commercial – New classroom, common area, offices, storage, minor food service metal building structure 2800 E 36TH ST TUCSON, AZ 85713 (R-1 Zoning) Commercial Building Plan Review – 3rd Review TRANSMITTAL DATE: November 17, 2026 1. COMMENT: Zoning has completed its review of the submitted building plan set and cross-referenced it against the associated Development Package. However, final approval of Commercial Permit TC-COM-0126-00127 cannot be granted until the associated revision to Development Package TD-DEV-0226-00031 has received full approval and has been issued. Per UDC §3.3.3.G, building permits for sites requiring a Development Package may not be issued prior to DP approval, as the building plans must be consistent with an approved site plan. Please resubmit for final approval once the Development Package has been approved and issued by all applicable reviewers. For final approval, ensure the building plans match the approved DP regarding footprint, proposed height, and square footage, and that the downspout and structure drainage systems shown in the building plans are consistent with those depicted in the Development Package plan set. 2. COMMENT: Additional comments may be forthcoming on the next review based on responses to Zoning and other PDSD reviewer comments. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: 3. COMMENT: Corrected commercial building permit (per any updates to TD-DEV-0226-00031). 4. COMMENT: Provide a detailed response letter with your submittal that clearly shows how you have addressed all Zoning comments. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home . Instructions for resubmittal - https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/tdc-faq/old-pdfs/double-old/resubmittals.pdf If you have any questions about this transmittal, please contact jeffrey.cassidy@tucsonaz.gov The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code . |
||
| 11/19/2026 | Water - PDSD Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00127 ADDRESS/PARCEL: 2800 E 36TH ST TUCSON, AZ 85713 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov. COMMENTS: 1. The plumbing plan on Sheet P101 and the pressure loss calculations table on Sheet P301 show a 1½-inch reduced pressure backflow preventer. However, the Development Plan and Site Utility Plan included in this drawing package as references show a new private 1-inch backflow preventer. Please coordinate the backflow preventer size between the Site Utility Plan and plumbing plans, and revise the drawings and pressure loss calculations as necessary. Reference: Section 107.2.1, IBC 2024. |
||
| 10/27/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |