Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0126-00112
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/12/2026 | Water - PDSD Standard | APPROVED | |||
| 01/30/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 02/18/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 02/19/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/18/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments.I can be reached at email mark.masek@tucsonaz.gov 1. Please amend plans to note or otherwise indicate compliance with Sec.7-137 #1. A readable sign shall be permanently attached and posted at the main entrance identifying the establishment as a massage establishment. The sign shall not be smaller than three (3) inches by five (5) inches and be of a durable material. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-5098 2. Please amend plans to note or otherwise indicate compliance with Sec.7-137 #6. Closed cabinets shall be provided, and used, for the storage of clean linens. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-5098 3. Please amend plans to note or otherwise indicate compliance with Sec.7-137 #7. Adequate dressing and toilet facilities shall be provided for patrons. The bathroom must be within the confines of the establishment. One (1) dressing room (may be the same as the massage treatment room), one (1) toilet and one (1) wash basin shall be provided by every massage establishment with one (1) to three (3) treatment rooms. Another toilet and wash basin must be provided when there are four (4) or more treatment rooms in an establishment. A minimum of one (1) shower or tub shall be provided for any establishment offering any hydrotherapy services such as whirlpool baths, saunas, steam baths, herbal wraps, etc. Each dressing room/treatment room shall contain a locker, lock box or cabinet for each patron to be served which shall be capable of being locked. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-5098 Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 02/18/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0126-00112 (1106 S WILMOT RD TUCSON, AZ 85711) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. Provide ‘as-built’ electrical and lighting plans showing compliance with Section 7-137(2) of the Tucson, Arizona Charter and General Ordinances, for electrical and lighting. |
||
| 02/12/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | Section 7-137 (3) of the Tucson, Arizona Charter and General Ordinances requires each room to have a supply and return register and/or a window that opens. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-5098 If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 02/12/2026 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Section 7-137 (7) of the Tucson, Arizona Charter and General Ordinances requires two restrooms for massage establishments having four or more treatment rooms. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az/0-0-0-5098 2. Clarify how the room labeled “shower” complies with the requirements of Sections 412.3 and 421, IPC 2024. 3. Is the existing water dispenser permanently connected to the water distribution system? Is a cup dispenser located adjacent to the water dispenser with the dispensing end between 34” and 48” above the finished floor. https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/2008-21_e_drinkingfountainpolicy.pdf If you have any questions about this review comment, I can be reached at Robert.Sherry@tucsonaz.gov. |
||
| 02/19/2026 | Site Zoning Standard | REQUIRES RESUBMIT | PDSD TRANSMITTAL FROM: Krista Hansen Planning & Development Services Department – Zoning Review Section PROJECT: TC-COM-0126-00112 1106 S WILMOT RD – C-2 Forest Spa C of O (1st Review) TRANSMITTAL DATE: 2/19/2026 Comments: Please resubmit revised drawings along with a detailed response letter which states how all Zoning Review Section comments were addressed. 01. COMMENT: As a general note, please add the number of required and provided motor vehicle and bicycle parking spaces (UDC Table 7.4.4-1 and Table 7.4.8-1). Clearly indicate that the requirements are met. 02. COMMENT: As a general note, please add the UDC Use and Use Specific Standards, which is, “Personal Service subject to UDC Section 4.9.13.P.” The Unified Development Code (UDC) can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes/Zoning-Code For questions regarding Zoning comments, please contact me at: Krista.Hansen@tucsonaz.gov |
||
| 02/19/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 01/28/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |