Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0126-00062
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/06/2026 | Site Zoning Standard | APPROVED | |||
| 02/04/2026 | Water - PDSD Standard | APPROVED | |||
| 02/04/2026 | Commercial Mechanical Standard | NOT REQUIRED | |||
| 02/04/2026 | Commercial Plumbing Standard | NOT REQUIRED | |||
| 01/26/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 02/03/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 02/09/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/05/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please provide plans, design and calculations prepared and sealed by a registrant licensed in Arizona Reference: Section 107.1, IBC 2024 and Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304. 2. The ballasted system must be designed to resist sliding and uplift resulting from lateral and vertical load combinations. Please submit certified structural calculations addressing these forces. IBC 107.2.7 3. Specify the coefficient of friction used in the sliding calculations and justify this value based on the type of roofing material (e.g., TPO, EPDM) and any specialized slip-sheet materials, such as protection pads. Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov | ||
| 01/26/2026 | Commercial Electrical Standard | REQUIRES RESUBMIT | Commercial Electrical Review TC-COM-0126-00062 (7990 E TANQUE VERDE RD TUCSON, AZ 85749) Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. Provide updated Plans/calculations and a written response Letter to each of the notated items indicating action taken. Resubmitted plans that do not contain a written response Letter addressing each of the notated items indicating action taken, may be delayed until response letter is received. Code reference, 2024 International Building Code (IBC), 2023 National Electrical Code (NEC). Contact Jeremy Hamblin with any questions: Jeremy.hamblin@tucsonaz.gov 1. This is a commercial project, requiring all documents to be prepared, sealed, signed, and dated by a registered design professional. Provide complete electrical plans, design, and calculations, sealed by an Arizona Registrant. Reference: Arizona Revised Statutes 32-125, Board of Technical Registration Rules R4-30-304, 2018 IBC section 107.1, 2017 NEC, City of Tucson Commercial Plan Submittal Requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Provide rapid shutdown labels and placard on the building, NEC 690.56(C) & 705.10. 3. Provide all warning labels and placards as required by 2023 NEC. Show the location of each warning label. Additional comments may be forthcoming with Registrant provided plans. |
||
| 02/09/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 01/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |