Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.1
Permit Number - TC-COM-0126-00057
Review Name: COMMERCIAL REVIEW - FULL v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/27/2026 | Commercial Electrical Standard | APPROVED | |||
| 02/03/2026 | Commercial Plumbing Standard | APPROVED | |||
| 02/06/2026 | Site Zoning Standard | APPROVED | |||
| 02/03/2026 | Water - PDSD Standard | APPROVED | |||
| 01/22/2026 | Outdoor Lighting Standard | NOT REQUIRED | No modifications to the outdoor lighting. | ||
| 01/16/2026 | Site Engineering Standard | NOT REQUIRED | |||
| 02/06/2026 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 02/05/2026 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. Additionally, please submit complete copies of all permit documents (i.e. plans, calculations, reports, etc.) even if they have not been changed. Please note the submittal was incomplete and the plan review was conducted using the information presented. The subsequent review could generate more comments after original comments have been addressed. Please contact me if you have any questions about the below comments. I can be reached at email mark.masek@tucsonaz.gov 1. Please amend the plans to include a structural detail demonstrating how the hood is connected to, supported by, and braced from the building structure. The detail shall clearly indicate attachment methods, support members, and any required bracing to ensure structural stability. 2018 IBC Section 107.2.1 Please contact me if you have any questions about the above comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 02/03/2026 | Commercial Mechanical Standard | REQUIRES RESUBMIT | ACTIVITY NO. TC-COM-0126-00057 ADDRESS/PARCEL: 1375 W AJO WY TUCSON, AZ 85713 Submit your revised drawings along with a detailed response letter, which states how all comments were addressed. Review will not proceed without the response letter. The submitted documents were incomplete and a thorough plan review could not be performed. Please be aware, new comments may arise with the next review. If you have any questions about these review comments, I can be reached at Sean.Severson@tucsonaz.gov COMMENTS: 1. Hood canopies shall extend at least 6” horizontally on all open sides beyond the edge of the top horizontal surface of the appliances (i.e. the pizza ovens) under the hood. Reference: Section 507.1.6.1, IMC 2024. 2. Revise detail A1/M501 to show how the new Type I hood is supported from the building structure. Reference: Sections 302.1 and 507.2.4, IMC 2024. 3. The mechanical plan, M102, shows two high velocity diffusers located in close proximity to the ends of the Type I hood. Verify that the location and type of air outlets complies with the hood manufacturer’s installation instructions and does not reduce the effectiveness of the exhaust system. Reference: Sections 304.1 and 508.1, IMC 2024. |
||
| 02/04/2026 | Fire New Construction Standard | REVIEW COMPLETED | |||
| 01/16/2026 | PDSD Application Completeness Express | REVIEW COMPLETED |