Permit Details

Status:
Inspections
Type:
Commercial Building
Address:
1375 W AJO WY
Address NEW:
1375 W AJO WY
Apply Date:
01/15/2026
Applicant:
Jaris Brenneman
Description:
Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.

Permit Reviews

Permit Number - TC-COM-0126-00057
Permit Status: Inspections
Permit Description: Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.
Start Date Submittal Complete Date Status  
03/16/2026 ADMINISTRATIVE v.1 03/16/2026 REQUIRES RESUBMIT Review Details
02/20/2026 COMMERCIAL REVIEW - FULL v.2 03/16/2026 APPROVED Review Details
01/15/2026 COMMERCIAL REVIEW - FULL v.1 02/06/2026 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-COM-0126-00057
Permit Status: Inspections
Permit Description: Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.
Total Outstanding Activity Conditions - 1
Date Name
02/03/2026 AIR BALANCING REPORT IS REQUIRED.

Conditions

Permit Number - TC-COM-0126-00057
Permit Status: Inspections
Permit Description: Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.
Date Description Comments
01/15/2026 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
01/15/2026 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-COM-0126-00057
Permite Description: Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.
Total Outstanding Inspections - 10
Last Inspection Date Description Inspector Results Comments
05/14/2026 COT - LCBU - Framing N/A Not Applicable 5-14-26: not applicable.
05/22/2026 COT - LCEL - Electrical Above Ceiling N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCPL - Plumbing Intermediate N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCME - Mechanical Final N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCBU - Building Final N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCME - Mechanical Intermediate N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCEL - Electrical Final N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCME - Kitchen Hood N/A Partial Pass 5-22-26: pending Fire approval.
05/22/2026 COT - LCEL - Electrical Intermediate N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.
05/22/2026 COT - LCPL - Plumbing Final N/A Re-inspection required 5-22-26: see previous notes regarding ceiling tiles, please provide ladder to inspect above ceiling, and access to rooftop is needed, oil reclaim tank missing insulation -see detail F1, reschedule inspections and have someone on site for walk through.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-COM-0126-00057
Permit Description: Includes reorganization of existing kitchen equipment and addition of new fryer units. The existing type 1 hood and wrapped ducts will be replaced with Type 1 new equipment. Rooftop equipment will remain existing.
Total Completed Inspections - 5
Date Description Inspector Results Comments
05/11/2026 COT - LCBU - Preslab Passed 5-11-26: under ground plumbing of floor drain verified under test and per plans. Also verified dowels at 16" o.c.-okay to backfill & continue with pour back.
05/14/2026 TRSP - ROW - Final/Close-Out Passed
05/22/2026 ENGR Engineering Final Passed
05/22/2026 COT - FCON - Fire - Final Passed
05/22/2026 COT - FCON - Hood System - Final Passed