Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0125-00139
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/14/2025 | Commercial Mechanical Standard | APPROVED | |||
| 04/15/2025 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/05/2025 | Commercial Building Standard | REQUIRES RESUBMIT | Please submit your revised documents and provide a letter with a written response letter addressing each of the comments indicating how the Review comments were resolved. COMMENT NOT ADDRESSED-2. Please provide the GEOTECHNICAL REPORT 24-077 BY PATTISON ENGINEERING, LLC DATED OCTOBER 31, 2024, with your next submittal. IBC 107.2.1 COMMENT NOT ADDRESSED- 3. Please provide the special inspection certificate with Part A, and Part B, completed with next submittal. IBC 107.2.1 https://www.tucsonaz.gov/files/sharedassets/public/v/1/city-services/planning-development-services/documents/special_inspection_certificate.pdf Please contact me if you have any questions about these comments. Mark Masek Plans Examiner – Building Safety Planning and Development Services | City of Tucson main 520.837.4994 email mark.masek@tucsonaz.gov |
||
| 04/15/2025 | Commercial Plumbing Standard | REQUIRES RESUBMIT | 1. Comment not addressed. [Initial comment: An approved development plan is not to be used for construction of on-site utilities (e.g. water service to the building, building sewer, etc.). Provide a site plan showing the installation of the water service to the building and for the installation of the building sewer from the building to the connection to the public sewer. Reference: Sections 107.2.1 and 107.2.6, IBC 2018.] 2. Section 504.6 (6), IPC 2018 states that the T&P relief must, “Discharge in a manner that does not cause personal injury or structural damage.” A person using an elevated service sink could be injured by hot water or steam from the water heater. Relocate the T&P discharge point. [Initial comment: Termination of the excess pressure relief from the water heater, P8, over an elevated service sink, P4, is not an approved location. Reference: Section 504.6 (6), IPC 2018.] |
||
| 04/07/2025 | Site Engineering Standard | REQUIRES RESUBMIT | See zoning comment | ||
| 04/03/2025 | Site Zoning Standard | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0125-00139 - TD-DEV-0125-00006 10096 E OLD VAIL RD. – PAD-36 Automotive: Minor Service and Repair (2nd Review) TRANSMITTAL: April 3, 2025 This site is located in PAD-36 (UDC 4.7.24). Automotive: Minor Service and Repair is an allowed use in the PAD. 1. Zoning has reviewed the building plans for compliance with development package TD-DEV-0125-00006 and although it appears that the plans are in compliance, Zoning is not able to approve the building plan until the DP is approved by all review agencies. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 03/18/2025 | PDSD Application Completeness Express | REVIEW COMPLETED |