Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.3
Permit Number - TC-COM-0124-00210
Review Name: COMMERCIAL REVIEW - FULL v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/07/2024 | Site Engineering | APPROVED | |||
| 04/19/2024 | Site Zoning | APPROVED | |||
| 05/07/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 04/18/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. The previous electrical plan review comments are not addressed completely. There was no written response to the electrical review comments located in the resubmittal. The plans need to be clear enough for the plan reviewer to determine exactly what the entire scope of work entails. 1 Please provide more detailed information on the plans as to the scope of work for this project. The job description entered with the submittal is to vague. It appears that there is a lot more proposed work than the stated,” Electrical equipment foundations and pipe supports”. Perhaps provide a scope of work narrative in the response or resubmittal. 2 Outdoor lighting modifications will require full compliance with the 2012 City of Tucson Outdoor Lighting Code. See Chapter 104 for plan submittal requirements. 3 Provide full compliance with NEC 500 articles for Hazardous area compliance where applicable. Ref; 2018 IBC section 107.2.1, City of Tucson Commercial Plan Submittal Requirements, 2017 NEC. |
||
| 04/19/2024 | Commercial Structural | REQUIRES RESUBMIT | Please address the Building plan review comments and provide a written response. Several of the building plan review comments are not addressed completely. There was no written response to the building review comments located in the resubmittal. The plans need to be clear enough for the plan reviewer to determine exactly what the entire scope of work entails. Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. The commercial submittal documents must be prepared by an Arizona licensed registrant. This would include the construction drawings and the structural calculations. IBC 197.2.1 and City of Tucson Commercial Submittal requirements. https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/checklists/commercial_submittal_requirements_july2023.pdf 2. Please provide a statement of special inspections, with next submittal IBC 1704 For example Concrete construction, Drilled foundations… 3. Please provide the structural calculations, prepared by an Arizona licensed registrant for this project with the next submittal. Keep in mind all the structural building code references should be the 2018 IBC as amended by the City of Tucson. IBC 107.2.1 and IBC Chapter 16 4. Please amend construction drawings to reference the 2018 IBC as amended by the City of Tucson. Additionally, all sheets of the drawing are to be sealed by an Arizona licensed registrant. 5. Please provide complete, detailed drawings. For example sheet 15 or BRT-23-291-FDN-11 does not provide concrete specification as noted on typical elevation detail. IBC 107.2 Mark Masek Plans Examiner Mark.masek@tucsonaz.gov 520-837-4994 |
||
| 03/20/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |