Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0124-00210
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/11/2024 | Commercial Mechanical | NOT REQUIRED | |||
| 03/11/2024 | Commercial Plumbing | NOT REQUIRED | |||
| 02/27/2024 | Fire New Construction | NOT REQUIRED | |||
| 03/11/2024 | Water - PDSD | NOT REQUIRED | |||
| 03/12/2024 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 03/07/2024 | Commercial Electrical | REQUIRES RESUBMIT | Please address the electrical plan review comments and provide a written response. 1. per the scope of work description, "Electrical equipment foundations and pipe supports". This may require the installation(s) of UFER type grounding electrode systems at the foundation or building footing. No electrical plans were submitted. Please clarify. Ref 2018 IBC section 107.2.1, 2017 NEC. |
||
| 02/20/2024 | Commercial Structural | REQUIRES RESUBMIT | Please submit your revised drawings along with a detailed response letter, which states how all Building Review Section comments were addressed. 1. Please provide the Soils report 23-002-Dated Feb.9. 2003 referenced in General noted, with your next submittal. IBC 107.2 2. Please provide a statement of special inspections, with next submittal IBC 1704 3. Please provide the structural calculations for this project with the next submittal. IBC Chapter 16 4. Please amend construction drawings to reference the 2018 IBC as amended by the City of Tucson. IBC 107.2 Mark Masek Plans Examiner Mark.masek@tucsonaz.gov 520-837-4994 |
||
| 03/12/2024 | Site Engineering | REQUIRES RESUBMIT | 1. A Development package will be required for this project. 2. Please provide equipment schedule and manufacturers pad requirements with resubmittal. Joshua Garcia joshua.garcia@tucsonaz.gov |
||
| 02/29/2024 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: TC-COM-0124-00210 8605 E OLD VAIL RD. – I-2 Electrical equipment foundations and pipe supports (1st Review) TRANSMITTAL DATE: February 29, 2024 DUE DATE: March 8, 2024 Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This site is located in the 1-2 zone (UDC 4.7.30). 1. Per UDC Article 3.3.3.G.2.c A site plan (Development Package) is required for the following types of development: Existing development undergoing a change of use, building structure additions, and/or a reconfiguration of an area outside a building. A development package (DP) meeting the requirements of Administrative Manual (AM) 2-06 must be submitted and approved prior to approval of this building plan. The Administrative Manual can be found at: https://www.tucsonaz.gov/Departments/Planning-Development-Services/Codes-and-Plans/Zoning-Code#section-1. Provide a copy of the approved DP for this project with your next submittal. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
| 02/06/2024 | PDSD Application Completeness Express | REVIEW COMPLETED |