Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.2

Permit Number - TC-COM-0124-00056
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
01/18/2024 Site Zoning APPROVED
02/07/2024 Site Engineering NOT REQUIRED
02/07/2024 Bldg Permits - Post Review PENDING ASSIGNMENT
01/29/2024 External Reviewers - SAFEBuilt REQUIRES RESUBMIT Structural(S) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/25/2024 2:36:04 PM
Structural review is approved. Subject to the field inspector's approval.




Building(B) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 1/29/2024 8:22:53 AM
1. Unresolved - Sheet a0.1: Incorrect code shown. The currently adopted accessibility code is the 2009 ICC/ANSI A117.1.

2. Unresolved - Sheets a0.1, a3: Thunder Canyon project does not show the correct occupant load as shown on the floor plans. Existing and expanded space totals 45 bar seats. (2018 IBC section 1004)

3. Unresolved - Sheets a0.1, a8: El Charro project does not include the existing and new areas in calculating the occupant loads. (2018 IBC section 1004)

4. Unresolved - Sheet a3: Only one accessible bar seat is shown on the floor plans but two are shown on the other sheets. 2018 IBC section 1109.11 requires a minimum of 5% of the seating/dining to be accessible.

5. Unresolved - Sheet a8: Show the accessible route to the accessible table in the new dining area. (2009 ICC A117.1 sections 802, 902, 2018 IBC sections 1109.11, 1104, 1108.2.9)

6. Unresolved - Sheet a12: Show the accessible dining space(s). 2018 IBC section 1109.11 requires a minimum of 5% of the seating/dining to be accessible.




Mechanical(M) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/25/2024 2:35:00 PM
Mechanical review is approved. Subject to the field inspector's approval.



Electrical(E) Reviewer
Keith Miller
kmiller@safebuilt.com
Denied
Reason:
Date Completed : 1/29/2024 8:23:34 AM
1. Unresolved - Sheet K-400: All kitchen receptacles are to be GFCI protected. (2017 NEC section 210.8(B)(2))



Plumbing(P) Reviewer
Keith Miller
kmiller@safebuilt.com
Approved
Reason:
Date Completed : 1/25/2024 2:35:33 PM
Plumbing review is approved. Subject to the field inspector's approval.
01/19/2024 Fire New Construction REVIEW COMPLETED
01/11/2024 PDSD Application Completeness REVIEW COMPLETED