Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - TC-COM-0124-00056
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/18/2024 | Site Zoning | APPROVED | |||
02/07/2024 | Site Engineering | NOT REQUIRED | |||
02/07/2024 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
01/29/2024 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Structural(S) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 1/25/2024 2:36:04 PM Structural review is approved. Subject to the field inspector's approval. Building(B) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 1/29/2024 8:22:53 AM 1. Unresolved - Sheet a0.1: Incorrect code shown. The currently adopted accessibility code is the 2009 ICC/ANSI A117.1. 2. Unresolved - Sheets a0.1, a3: Thunder Canyon project does not show the correct occupant load as shown on the floor plans. Existing and expanded space totals 45 bar seats. (2018 IBC section 1004) 3. Unresolved - Sheets a0.1, a8: El Charro project does not include the existing and new areas in calculating the occupant loads. (2018 IBC section 1004) 4. Unresolved - Sheet a3: Only one accessible bar seat is shown on the floor plans but two are shown on the other sheets. 2018 IBC section 1109.11 requires a minimum of 5% of the seating/dining to be accessible. 5. Unresolved - Sheet a8: Show the accessible route to the accessible table in the new dining area. (2009 ICC A117.1 sections 802, 902, 2018 IBC sections 1109.11, 1104, 1108.2.9) 6. Unresolved - Sheet a12: Show the accessible dining space(s). 2018 IBC section 1109.11 requires a minimum of 5% of the seating/dining to be accessible. Mechanical(M) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 1/25/2024 2:35:00 PM Mechanical review is approved. Subject to the field inspector's approval. Electrical(E) Reviewer Keith Miller kmiller@safebuilt.com Denied Reason: Date Completed : 1/29/2024 8:23:34 AM 1. Unresolved - Sheet K-400: All kitchen receptacles are to be GFCI protected. (2017 NEC section 210.8(B)(2)) Plumbing(P) Reviewer Keith Miller kmiller@safebuilt.com Approved Reason: Date Completed : 1/25/2024 2:35:33 PM Plumbing review is approved. Subject to the field inspector's approval. |
||
01/19/2024 | Fire New Construction | REVIEW COMPLETED | |||
01/11/2024 | PDSD Application Completeness | REVIEW COMPLETED |