Permit Review Detail
Review Status: Requires Resubmit
Review Details: COMMERCIAL REVIEW - FULL v.2
Permit Number - T22CM07932
Review Name: COMMERCIAL REVIEW - FULL v.2
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/15/2023 | Bldg Permits - Post Review | PENDING ASSIGNMENT | |||
03/13/2023 | External Reviewers - SAFEBuilt | REQUIRES RESUBMIT | Activity Number: T22CM07932/CONVENIENT STORE AND T22CM07933/FUEL CANOPY GENERAL: Provide written responses to all review comments. Provide a complete plan set. Provide additional documents as requested by review staff. STRUCTURAL REVIEW COMMENTS: Conditionally Approved NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances. BUILDING REVIEW COMMENTS: Approved MECHANICAL REVIEW COMMENTS: Conditionally Approved Approved/subject to field approval ELECTRICAL REVIEW COMMENTS Conditionally Approved E001: Could not locate Keyed Note #14 E004: No plan notes actually on the sheet. E005: No security shown. Not needed for electrical permit. E104: Could not locate Plan Note #4. E602: May need to upsize conductors for item 217 as it is probably a continuous load. PLUMBING REVIEW COMMENTS: Denied Second Plumbing Review: 1). SAME-Add restroom fixture spacing measurements to plan page P201 or A214. -IPC 404.2, 405.3.1 2). OK 3). SAME-#612 Handsink on plan page P202 detail #F11 can't discharge indirectly -IPC802.1**Version 2 not provided ** 4). SAME- Steam & oven drains on plan page P202 need to comply with -IPC 702.5 if discharge is over 140 Deg. ** Specification Attachments not included as per response narrative** 5). SAME- P511 detail A13 pump discharge line needs a shut off valve on discharge side of check valve. -IPC 712.2, 1113.1.4**Version 2 not provided ** 6). OK - Per response Canopy run-off is secondary drain 7). SAME-Notate on P104 the total GPM or square footage the 3" canopy roof drains will be handling. -IPC 1106.2 **Version 2 not provided & response comment doesn't correlate** 8). SAME- Add the piping materials for water, sanitary, storm to the plumbing plans or supply spec manual. - IPC Chapter 6, 7, 11 ** Spec Manual Not included** If you require additional clarification regarding these comments, please contact Doris Benoit at doris.benoit@tucsonaz.gov |
||
03/15/2023 | Site Engineering | REQUIRES RESUBMIT | See zoning comment | ||
03/14/2023 | Site Zoning | REQUIRES RESUBMIT | CDRC Transmittal FROM: Zoning Review Section PROJECT: T22CM07932 QuickTrip No 1499 (2nd review) New General Merchandise – Convenience Store TRANSMITTAL DATE: March 14, 2023 DUE DATE: March 18, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 01. COMMENT: Zoning has done a cursory review of the building plans and although the site plan appears to match the associated development package, zoning cannot approve the building plans until DP22-0074 has been approved and the building plans have been reviewed for consistency. If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov. |
||
02/21/2023 | Fire New Construction | REVIEW COMPLETED | |||
02/16/2023 | PDSD Application Completeness | REVIEW COMPLETED |