Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T22CM07804
Parcel: 13707041B

Address:
5201 S 12TH AV

Review Status: Requires Resubmit

Review Details: COMMERCIAL REVIEW - FULL v.5

Permit Number - T22CM07804
Review Name: COMMERCIAL REVIEW - FULL v.5
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
05/30/2023 External Reviewers - SAFEBuilt APPROVED Activity Number: T22CM07804

GENERAL:
Provide written responses to all review comments.
Provide a complete plan set.
Provide additional documents as requested by review staff.

Structural(S) Reviewer
Daljit Benipal
dbenipal@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 1/9/2023 10:00:24 AM
NOTE: Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The Structural Engineer is responsible for following ALL applicable Federal, State and local Municipal Codes and Ordinances.


Building(B) Reviewer
Andrew Bevis
abevis@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 12/29/2022 10:29:30 AM
Conditionally approved, per the following:
Every effort has been made to identify the code violations. Any oversight by the review team shall not be considered an authority to violate, set aside, cancel, or alter applicable codes or ordinances. The plan review and permit issuance shall not be considered a warranty or guarantee. The registered design professional is responsible for following ALL applicable Federal, State, and local Municipal Codes and Ordinances.


Mechanical(M) Reviewer
Neil Samaan
nsamaan@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 5/26/2023 6:33:03 PM
3. Provide manufacturers specs for hood 1 and hood 2 (IMC2018,106.3.1) this is the information required on the specs which you have not provided Complied
5. Provide refrigeration schedule including specs for walk in coolers and freezers and condensing unit information including amount and type of refrigeration (IMC2015,106.3.1) The condensing units for all walk in coolers need to be in the mechanical schedule with all pertinent information Complied
Approved/subject to field approval


Electrical(E) Reviewer
Ron Ross
rross@safebuilt.com
Conditinally Approved
Reason:
Date Completed : 10/26/2022 6:14:55 PM
Electrical Review of El Guero Canelo
By: Ron Ross PE
E4.0 ELECTRICAL PANEL SCHEDULES: Discrepancy between One Line Diagram Feeder Schedule and feeder shown between CT Can and Panel LD.

Plumbing(P) Reviewer
Perry Hendershott
phendershott@safebuilt.com
Conditionally Approved
Reason:
Date Completed : 5/29/2023 3:17:02 PM
Fifth Plumbing Review: OK Subject to field Inspections
1). ** See Building Official letter **The #13 Ice machine on plan page P1 can't discharge to the grease interceptor. -IPC 1003.2 ** Subject to Field Inspections**
2). . ** See Building Official letter ** The M4 , #18, #31 walk-in coolers condensate on plan page P1 can't discharge to the grease system. -IPC 1003.2**Subject to Field Inspections**
3). . ** See Building Official letter **HP1, HP3, EC1 condensate on plan page P1 can't discharge to the grease system. -IPC 1003.2 ** Subject to Field Inspections**
4).OK
5). OK- Hand sink next to outdoor grill on plan page P1 needs overhang above, it can't receive rain water. -IPC 1101.3 **
Exterior sink to have cover to prevent stormwater see See Plan pages A3 & A17**
6). OK
7).. ** See Building Official letter ** Per the manufacturer website the GB-250 grease interceptor selected on plan page P6 is a hydromechanical type. The Tucson plumbing code amendments only allow 4 items to discharge to this type of grease interceptor. Update all affected plumbing pages** Subject to Field Inspections**
8).OK- Adjacent Overflow wall scupper added to plan pages A8 & A17
9). OK
10).OK
11). OK
12). OK
13).OK
06/29/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
06/29/2023 Historic REQUIRES RESUBMIT Request for historic demo documentation were requested under this permit number, please submit the information so this item can be cleared.
06/13/2023 Site Engineering REQUIRES RESUBMIT See zoning comment
06/06/2023 Site Zoning REQUIRES RESUBMIT FROM: PDSD Zoning Review Section

PROJECT: T22CM07804
5201 S 12th Av
New Food Service building (4th Review)

TRANSMITTAL DATE: June 06, 2023

Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed.

1. Zoning has reviewed the building plans for compliance with DP22-0124. Although it appears that the building plan matches the DP, Zoning cannot approve the building plan until the DP is approved.

If you have any questions about this transmittal, please contact Zone1.desk@tucsonaz.gov.
05/25/2023 PDSD Application Completeness Express REVIEW COMPLETED