Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.1
Permit Number - T22CM05735
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/04/2023 | Site Engineering | NOT REQUIRED | |||
| 01/12/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/05/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM05735 SFR 1952 W KING AV Zoning R-1 TRANSMITTAL DATE: January 5, 2023 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. This comment is still applicable, it appear that the Pet pen has a roof, please provide pictures that all the structure have been removed and the Pen is just a roof area, Clarify which types of animals are proposed to be in the pet pen. 1.COMMENT: Clearly show everything on site. Based on current aerial photos there are three possible unpermitted structures on the site. Additional comments may be forth coming. https://gis.pima.gov/pictometry/ipa/IPAfullnet/llviewer.aspx?lat=32.197&lon=-111.0079 This comment is still applicable, clarify of the location of the temporary workshop, if the workshop is to be removed remove it from the area calcs. Provide pictures showing the removal of the unpermitted structures. 2.COMMENT: There is an expired New SFR permit T18CM06075, with pending inspections, this permit must be finaled prior to zoning approval of this building permit. Please provide permit documentation for the other structures on the site. 3.COMMENT: The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 14’6” the required perimeter yard setback from the proposed SFR to the north property line is 9’-9”, proposed setback is 6’-0”. A Design Development Option (DDO) must be submitted and approved to reduce the required setback, DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 01/06/2023 | Zoning Modifications - DDO | REQUIRES RESUBMIT | The site is zoned R-1 residential (UDC 4.7.8) and is surrounded by R-1 zoning as well. Per UDC Table 6.3-2.A: Dimensional Standards for the R-1, R-2, R-3, MH-1, & MH-2 Zones, when a residential use is adjacent to a residential zone, the required interior setbacks are six feet or 2/3 the height of the exterior wall, whichever is greater, measured from the property line. Based on a wall height of 14'-6", the required setback from the north property line is 9'-8"; proposed is 6'-0". A Design Development Option (DDO) must be submitted and approved to reduce the required setback. The DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/2019_DDO_for_Setback_and_Height_UDC.pdf. Please note that all Zoning comments shall be addressed prior to submittal of the DDO application. If the roofed area of the "existing fenced-in pet pen" is to remain, a Board of Adjustment variance is required as the structure has a zero-foot setback. Please contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951 should you have questions about this transmittal. |
||
| 01/04/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 01/12/2023 | Residential Building | REVIEW COMPLETED |