Permit Number: T22CM02217
Parcel: 130103140

Address:
3235 E 30TH ST

Review Status: Requires Resubmit

Review Details: RESIDENTIAL NEW DWELLING v.1

Permit Number - T22CM02217
Review Name: RESIDENTIAL NEW DWELLING v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
10/12/2023 Residential Building APPROVED
10/12/2023 Bldg Permits - Post Review Express PENDING ASSIGNMENT
10/04/2023 Site Zoning REQUIRES RESUBMIT ZONING REVIEW TRANSMITTAL

FROM: Wyatt Berger
Lead Planner

PROJECT: T22CM02217
3225 E 30th St - R-1
ADU (3rd review)

TRANSMITTAL DATE: October 4, 2023

COMMENTS: The following comments are relative to a Board of Adjustment variance (UDC 3.10.3) or a Design Development Option (DDO) (UDC 3.11.1).

1. Remove all references to a sleeping quarters on all sheets as a sleeping quarters does not contain any cooking facilities such as proposed.

2. This comment was not addressed. Per UDC Article 6.6.3.B.5, for lots equal to or greater than 6,500 square feet, the accessory dwelling unit is limited to 10% of the lot size, not the exceed 1,000 square feet of gross floor area. Based on a lot size of 7,050 square feet, the maximum gross floor area of an accessory dwelling unit on this lot is 705 square feet gross floor area. The proposed accessory dwelling unit exceeds the allowed 10% of total size. A Board of Adjustment variance will be required to exceed this requirement.

3. This comment was not addressed. Include the laundry and bathroom additions as depicted in T22CM02218 in the lot coverage calculation for this specific plan set.

4. Add a general note on the site plan stating the accessory dwelling unit will be developed with a high albedo level (>60 SRI) or other cool roof technology per the ICC Green Construction Code to comply with UDC 6.6.3.B.3.

5. Per UDC 6.4.5.B, setbacks are measured between the property line to the face of each exterior building wall at the wall's highest point. The minimum required side perimeter yard setback is the greater of 6'-0" or 2/3 the height of the exterior building wall (Table 6.3.2-A). Based on a wall height of 11'-11", measured from design grade to the wall's highest point, the minimum required setback to the east lot line is approximately 7'-11"; proposed is 7'-6". A Design Development Option application must be submitted and approved to reduce the required setback to the east lot line. If a variance is pursued for comment 1, this setback reduction may be included within the variance process.

Contact Mark.Castro@tucsonaz.gov if you have any questions about the variance or DDO process.

If you have any questions about this transmittal, please contact me at Wyatt.Berger@tucsonaz.gov or at 520-837-4951.
09/25/2023 PDSD Application Completeness Express REVIEW COMPLETED