Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.2
Permit Number - T22CM02217
Review Name: RESIDENTIAL NEW DWELLING v.2
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/06/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 12/06/2023 | Site Zoning | REQUIRES RESUBMIT | FROM: Paul Camarena PDSD Zoning Review Section PROJECT: T22CM02217 3235 E 30TH ST Zoning R-1 TRANSMITTAL DATE:December 6, 2023 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1.COMMENT: This site is located in the Approach departure corridors (ADC) for DMAFB. PER UDC section 5.6.8.3.d.2 “Residential development is limited to no more than one dwelling unit per acre .” With that being said, an ADU will not be allowed. 2.COMMENT: If this structure is to be a sleeping quarters, the following comments are applicable. Per UDC 6.4.5.B, setbacks are measured between the property line to the face of each exterior building wall at the wall's highest point. The minimum required side perimeter yard setback is the greater of 6'-0" or 2/3 the height of the exterior building wall (Table 6.3.2-A). Based on a wall height of 11'-11", measured from design grade to the wall's highest point, the minimum required setback to the east lot line is approximately 7'-11"; proposed is 7'-6". At a minimum, a neighbor’s setback waiver is required to reduce the perimeter yard setback. To secure this waiver the following text shall be provided on the plot plan and be signed and dated by the owner of the property to the east: My Name is____________________ and I am the owner of the property located at_______________________. I have reviewed the site plan and I have no objection to structure being located or constructed________ feet from the property line as depicted on the site plan. Signature: _____________________________ Date: _________________________________ If you are unable to secure the neighbor’s setback waiver a Design Development Option (DDO) will need to be processed and approved to reduce the setback. DDO application and requirements can be found at: https://www.tucsonaz.gov/files/sharedassets/public/pdsd/documents/planning-amp-zoning/2019_ddo_for_setback_and_height_udc.pdfGeorgia.Pennington@tucsonaz.gov COMMENT: Provide a calculation, Per UDC Article 6.6.3.E “The total gross floor area (gfa) of all accessory structures shall not exceed 50% of the gfa of the principal structure . Accessory structures less than 200 square feet gfa and accessory dwelling units are exempt from this requirement”. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 11/24/2023 | PDSD Application Completeness Express | REVIEW COMPLETED |