Permit Review Detail
Review Status: Requires Resubmit
Review Details: RESIDENTIAL NEW DWELLING v.3
Permit Number - T21CM06656
Review Name: RESIDENTIAL NEW DWELLING v.3
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/10/2023 | Site Engineering | NOT REQUIRED | |||
| 04/04/2023 | Bldg Permits - Post Review Express | PENDING ASSIGNMENT | |||
| 01/12/2023 | Site Zoning | REQUIRES RESUBMIT | ZONING REVIEW TRANSMITTAL FROM: PDSD Zoning Review PROJECT: T21CM06656 935 S Fremont Ave. – R-2 New SFR & Detached Sleeping Quarters (2nd Review) TRANSMITTAL: January 12, 2023 This site is located in the R-2 zone (UDC 4.7.9). Multi-family residential is a permitted use in this zone (Table 4.8-2). See Use Specific Standards 4.9.7.B.6, .9 & .10. This comment is still applicable. 1. As some type of land split/lot line reconfiguration has be done provide approved lot split documents with your next submittal. -Revise the property line dimension as they appear to be incorrect. The following comments are relative to an application for a Design Development Option (DDO) (UDC 3.11.1). The following comments are for the proposed SFR, 2.The minimum setback is the greater of six (6) feet, or two-thirds (2/3) the height of the structure’s wall facing each interior property line (Table 6.3-2.A). Based on a wall height of 22’-0” the required perimeter yard setback from the proposed SFR to the north and south property line is 14’-9”, proposed setback to the north & south property line is 11’-0”. 3.The minimum setback to the front street perimeter property line is the greater of twenty (20) feet, or one and one-half (1 ½) the height of the proposed wall (UDC 6.4.5.C.1.a). Based on a wall height of 22’-0” the required front street perimeter yard setback is 33’-0” proposed front street setback is 25’-0” DDO application and requirements can be found at: https://www.tucsonaz.gov/files/pdsd/forms/DDO_for_Setback_and_Height_UDC_8.11.20.pdf. A DDO is a separate submittal from the building plan and shall be submitted at: https://tdc-online.tucsonaz.gov/#/ . If you have questions about the DDO application or process please contact Mark Castro at Mark.Castro@tucsonaz.gov. If you have any questions about this transmittal, Contact Paul Camarena at (520)837-4986 or by email Paul.Camarena@tucsonaz.gov |
||
| 01/10/2023 | Fire New Construction | REVIEW COMPLETED | Questions: Jennifer Peel-Davis Tucson Fire Department Fire Plans Examiner Fire Inspector I, II and Fire Alarm Plans Examiner Jennifer.Peel-Davis@Tucsonaz.gov Desk: 520-837-7033 |
||
| 01/04/2023 | PDSD Application Completeness Express | REVIEW COMPLETED | |||
| 02/01/2023 | Residential Building | REVIEW COMPLETED | |||
| 04/04/2023 | Zoning Modifications - DDO | REVIEW COMPLETED |