Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE REVIEW v.1
Permit Number - DP22-0100
Review Name: DEVELOPMENT PACKAGE REVIEW v.1
Review Status: Requires Resubmit
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
10/31/2022 | Fire New Construction | APPROVED | |||
10/27/2022 | Site Engineering | APPROVED | |||
10/31/2022 | Site Zoning | APPROVED | |||
10/27/2022 | Traffic Engineering Review | APPROVED | |||
10/31/2022 | CDRC Post Review | PENDING ASSIGNMENT | |||
10/31/2022 | Site Landscape | REQUIRES RESUBMIT | CDRC TRANSMITTAL TO: Planning and Development Services Department, Plans Coordination FROM: Anne Warner, RLA PDSD Landscape/Native Plant Preservation Section PROJECT: North Tucson Commerce Center ACTIVITY NO: DP22-0100 v3 Address: 2780 E Valencia Rd Zoning: I-1 Existing Use: undisturbed Sonoran Desert Proposed Use: Distribution Center TRANSMITTAL DATE: September 7, 2022 DUE DATE: September 1, 2022 COMMENTS: Please resubmit revised drawings along with a detailed response letter, which states how all Landscape Review Section comments were addressed. This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants and water harvesting. General Note - UDC 2-10.4.1 Identification and Descriptive Data - All improvements and site information, such as adjacent rights-of-way and property lines, shown on the landscape plan will be identical in size and location to those shown on the base plan (site plan or tentative plat). Should amendments be required to the base plan through the review process, the same amendments will be made to the landscape plan which will then be resubmitted along with the base plan. 1. This comment was not adequately addressed - Please label the existing and future rights of way for all public streets, UDC 7.6.4.C.2.a. 2. It appears that there is landscaping within the rights of way. Please contact David.marhefka@tucsonaz.gov for permission to use up to 5’ of the right of way. Plans cannot be approved without the department’s consent. 3. This comment was not adequately addressed - The ERR requires exhibits that show floodplain, riparian area and proposed disturbance, as well as mitigation. Please refer to Tech Standards 4-01.2.5.B for content requirements. There is no “minor” ERZ report. 4. This comment has not been completely addressed. All water from the roof and parking area on the south has been graded to direct runoff to the basin. No water seems to going to the landscape border on the east. UDC section 7.6.6.C requires the use of all runoff to supplement irrigation. Show how this is attained. Water harvesting has not yet been maximized. UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening. 5. This comment was not adequately addressed - Water harvesting areas should be depressed between 6 and 9 inches. Please ensure that 6-9” depth is achieved after 2” placement of d.g. (details, notes should show a 8-11” depth. 6. This comment has not been adequately addressed along the south border, identify curb inlets/splash pads to landscape areas on water harvesting or landscape plans. Add flow arrows showing how water is draining to the south and west landscape areas. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package YOUR NEXT STEPS: Submit documents to the Filedrop https://docs.tucsonaz.gov/Forms/tucsonpermitapp Select "Existing Application" 1) Comment Response Letter (your response to the reviewer's Requires changes comments) 2) Plan Set (or individual sheets) 3) Any other items requested by review staff If you have any questions, please contact me at anne.warner@tucsonaz.gov |