Permit Review Detail
Review Status: Requires Resubmit
Review Details: DEVELOPMENT PACKAGE NEW REVISION v.1
Permit Number - DP21-0325
Review Name: DEVELOPMENT PACKAGE NEW REVISION v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/10/2025 | Site Engineering Standard | REQUIRES RESUBMIT | Permit: DP21-0325 Location: 841 E BANTAM RD Review Date: 11/10/2025 Site Engineering Comments: 1. When bollards or architectural features (Wheel Stops) are used to provide physical separation, the maximum separation between the barriers is five feet clear. Technical Standards Manual 7-01.4.2.B. 2. The pathway that goes 90 degrees across the PAAL will not be sufficient due to someone now walking alongside and across the PAAL. It is a recommendation that this pathway be removed entirely and the two ADA pathways down the center of the development simply be connected through a hatched path to complete pedestrian circulation. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
||
| 11/25/2025 | Site Landscape Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL PLANNING AND DEVELOPMENT SERVICES DEPARTMENT REVIEWER: BOBBY PARSONS - PLANNER PDSD LANDSCAPE/NATIVE PLANT PRESERVATION SECTION PROJECT: IGLESIA DE CRISTO CHURCH – ADDITION TO BUILDING ACTIVITY NO: DP21-0325 (REVISION 1 – NEW PARKING LOT) ADDRESS: 841 E BANTAM RD. TUCSON, AZ 85706 ZONING: R-2 This plan has been reviewed for compliance with applicable development criteria in the City of Tucson Unified Development Code (UDC) Administrative Manual (AM) Section 2-11 and Technical Manual (TM) Section for landscape, native plants, and water harvesting. Please resubmit revised drawings along with a detailed response letter, which states how all Landscape/NPPO Review Section comments are addressed. 1. Comment: As this revision proposes 8 additional parking spaces, please update the landscape plan to show the minimum required trees (1 tree for every 4 new parking spaces). 2. Comment: Depress the planting area in the parking lot 6” to maximize rainwater harvesting onsite. 3. Comment: Please update the landscape plans to show the required irrigation to the new parking lot trees. If you have any questions about this transmittal, please contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. |
||
| 11/21/2025 | Site Zoning Standard | REQUIRES RESUBMIT | CDRC TRANSMITTAL FROM: Bobby Parsons PDSD Zoning Review Section PROJECT: 841 E. Bantam Rd. Tucson, AZ 85706 Development Package (1st Revision Review) DP21-0325 TRANSMITTAL DATE: 11/21/2025 DUE DATE: 11/25/2025 COMMENTS: Please resubmit revised drawings and any redlined plans along with a detailed response letter, which states how all Zoning Review Section comments were addressed. Section 3.3.3.G.5.c UDC, An applicant has one year from the date of application to obtain approval of a site plan that complies with zoning and other development requirements in effect at the time of application, unless an ordinance adopted by Mayor and Council during this period states otherwise. A site plan application that has been in review for a period of one year and has not yet been approved is considered denied. To continue the review of a site plan for the property, a new site plan must be submitted that complies with regulations in effect at the time of re-submittal. The new submittal initiates a new one-year review period. One year Expiration date is October 30, 2026. SECTION 2-06.0.0: DEVELOPMENT PACKAGE (TENTATIVE PLATS AND SITE PLANS) 2-06.4.7 - General Notes The following general notes are required. Additional notes specific to each plan are required where applicable. Zoning and Land Use Notes 2-06.4.7.A.8 - For development package documents provide: 2-06.4.7.A.8.a - Floor area for each building; 1. COMMENT: 2-06.4.7.A.8.a – Please update the floor area to include the ramada as noted by the standard above. 2-06.4.7.A.8.b - Percentage and area in square feet of building and accessory building coverage; 2. COMMENT: 2-06.4.7.A.8.b – As you are proposing a new ramada, please update the percentage and area in square feet as noted by the standard above. 2-06.4.8 - Existing Site Conditions The following information shall be provided on the plan/plat drawing to indicate the existing conditions on site and within 50 feet of the site. On sites bounded by a street with a width of 50 feet or greater, the existing conditions across the street will be provided. 2-06.4.9 - Information on Proposed Development The following information on the proposed project shall be shown on the drawing or added as notes. 2-06.4.9.O - All applicable building setback lines, such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. 3. COMMENT: 2-06.4.9.O – Draw, label, and dimension the setbacks from the property line to the new ramada as noted by the standard above. 2-06.4.9.Q - Provide the square footage and the height of each commercial, industrial, or business structure and the specific use proposed within the footprint of the building(s). 4. COMMENT: 2-06.4.9.Q – Please provide the information as noted by the standard above within the footprint of the new ramada. 2-06.4.9.R - Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. 5. COMMENT: 2-06.4.9.R – Please see Site Engineering comments as it relates to pedestrian circulation along the new PAAL. ***For additional information on the any standard presented in this memo, please refer to the City of Tucson “Unified Development Code” – Administrative Manual Section 2-06 or Technical Standards noted in the comments. https://www.tucsonaz.gov/pdsd/all-codes-plans-determinations If you have any questions about this transmittal, Contact Bobby Parsons at Robert.Parsons@tucsonaz.gov. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package and comment response letter. To resubmit visit Tucson Development Center at https://tdc-online.tucsonaz.gov/#/home. Instructions for resubmittal - https://www.tucsonaz.gov/files/pdsd/website/Resubmittals.pdf. |
||
| 11/03/2025 | CDRC Review Coordinator Express | REVIEW COMPLETED | NO EXTERNAL REVIEWERS External Reviewers not required. No further action is required from the customer at this time. Site Zoning, Site Engineering, Site Landscape |
||
| 10/31/2025 | OK to Submit - Engineering Fast | REVIEW COMPLETED | |||
| 10/30/2025 | OK to Submit - Zoning Fast | REVIEW COMPLETED |