Review Status: Requires Resubmit

Review Details: CIP - COMMERCIAL STRUCTURE - INITIAL v.1

Plan Number - CIP-0824-00025
Review Name: CIP - COMMERCIAL STRUCTURE - INITIAL v.1
Review Status: Requires Resubmit
Review Date Reviewer's Name Type of Review Description Status Comments
Traffic Engineering Review APPROVED Traffic Engineering has no comments on this project located outside of the ROW,
Archeological Sensitivity Complex NOT REQUIRED No new ground disturbance. Chargers to be attached to existing concrete.
Design Review NOT REQUIRED Fire station is not an approved IID project.
Zoning Administration NOT REQUIRED
Zoning Compliance Review NOT REQUIRED
Bldg Permits - Post Review Express REQUIRES RESUBMIT ACTIVITY NO. CIP-0824-00025
PROJECT: EV CHARGING STATION FOR FIRE CENTRAL
ADDRESS/PARCEL: 300 S FIRE CENTRAL PL/117-13-069E

Plan review for the above referenced project has been completed. This letter reflects comments to be addressed.


COMMENTS:
1. Please address all comments provided by the following departments:
a. Commercial Building
b. Commercial Electrical
c. TW New Development
d. Site Landscape
e. Site Zoning
f. TW Planning and Engineering Review
2. Include a revision letter outline where and how all of these corrections have been addressed.

More comments may be forth coming once corrections have been made.

If you have any questions about these comments, I can be reached at Matthew.Carlton@tucsonaz.gov
Building Official REVIEW COMPLETED
Commercial Building REVIEW COMPLETED Please enter a statement within your Cover Sheet as to the possible need for a Handicap Accessible EV Charger and how this is being addressed.
Commercial Electrical REVIEW COMPLETED Please address the electrical plan review comments and provide a written response.

1. REF; Plan sheet E1.0. Electrical Plan Lower Level 1. There is a KEY NOTE #4 to the east of the plan that appears to be misplaced. Please fix.

2. REF; Plan sheet E0.2 and E2.0. The EV Charger Feeder Schedule shows all the EV feeders in 1” conduit with 2- #8, #10 equipment ground for each EV feeder. Per NEC 310.15(B)(C) 75c column. #8 AWG cu is rated at 50 amps. The panel schedule for panel ‘EV’ shows 100 amp OCPD’s protecting these feeders. The feeders are undersized. Please clarify.

3. REF; Plan sheet E0.2. Why is the EPO Push Button installed on EV2 and EV4. EV4 is Future. Also provide a wiring schematic and explain how the EPO operates. There is no EPO feature indicated in the EV Charging Station specifications. Please clarify.

4. REF; Plan sheet 2.0. Please indicate the correct fuse rating in ‘MSB’ that protects the feeder for the 400 amp disconnect.

5. REF; E2.0. For clarity, identify the 400 amp disconnect in the line diagram and correlate with the Equipment Circuit Description and CKT shown in the schedule for ‘MSB’.

6. REF; Plan sheet E2.0. A note in the Line Diagram states, “SEE SCHEDULE FOR BREAKER SIZES AND QUANTITIES”. Which schedule? The panel schedule for PANEL NO: ‘MSB’ does not make any sense. How do CKTs #1 thru #12 correlate with this SWITCHBOARD? Are all these Breaker Sizes and Quantities associated with MSB Switchboard? It does not seem apparent. For clarity, please provide a complete ‘ONE LINE FEEDER SCHEDULE’.

REF; 2018 IBC section 107.2.1, 2017 NEC.
Commercial Mechanical REVIEW COMPLETED
Commercial Plumbing REVIEW COMPLETED
Fire New Construction REVIEW COMPLETED no comments at this time
Historic REVIEW COMPLETED No new ground disturbance. Chargers to be attached to existing concrete.
ROW Engineering Review REVIEW COMPLETED DTM has no comments.
Signs REVIEW COMPLETED
Site Engineering REVIEW COMPLETED
Site Landscape REVIEW COMPLETED CDRC TRANSMITTAL
PLANNING AND DEVELOPMENT SERVICES DEPARTMENT
REVIEWER: CHAD KELLER, RLA
PDSD SITE LANDSCAPE/NATIVE PLANT PRESERVATION SECTION

PROJECT: PROVIDE (2) NEW EV CHAGERS FOR FIRE CENTRAL
ACTIVITY NO: CIP-0824-00025
ADDRESS: 300 S FIRE CENTRAL PL
ZONING: C-3 COMMERCIAL ZONE

SITE LANDSCAPE/NPPO SECTION COMMENTS:

1. Provide a note and possibly a protective fencing detail for the existing trees near the EV chargers and the buried electrical wiring conduit.

If you have any questions about this comment, I can be reached at chad.keller@tucsonaz.gov
Site Zoning REVIEW COMPLETED CDRC TRANSMITTAL
TO: Development Services Department
Plans Coordination Office
FROM: Loran Shamis, Project Manager
PDSD Zoning Review Section
PROJECT: CIP-0824-00025 – Initial review

1. COMMENT: An index of sheets in the development package shall be provided on the first sheet. Label the sheets in the index and in the title block as Sheet XX of XX.

2. COMMENT: The name, mailing and email addresses, and phone number of the primary property owner of the site, the developer of the project, registrant(s), and other person(s), firm(s), or organization(s) that prepared the development package documents shall be provided on the right half of the cover sheet. The applicable registration or license number shall be provided if prepared by or with the assistance of a registered professional, such as a surveyor, architect, landscape architect, or engineer. All sealing shall be consistent with Arizona Board of Technical Registration guidelines.

3. COMMENT: Include a brief legal description in the title block.

4. COMMENT: Include a note stating the existing zoning is C-3.

5. COMMENT: List the gross area of the site by square footage and acreage.

6. COMMENT: Include a general note stating the use is Civic – Protective Services (government owned and operated).

7. COMMENT: Include the entire site in the site plan including the property boundaries and 50’ beyond the property lines.

8. COMMENT: If applicable, all existing easements shall be drawn on the plan. The recordation information, location, width, and purpose of all easements on site will be stated.

9. COMMENT: The following information regarding existing private or public right-of-way adjacent to or within the site shall be provided: the name, right-of-way width, recordation data, type and dimensioned width of paving, curbs, curb cuts, and sidewalks.

10. COMMENT: Label the existing zoning classifications for the site and the adjacent properties. All existing zoning classifications on and adjacent to the project (including across any adjacent right-of-way) shall be indicated on the drawing with zoning boundaries clearly defined.

If you have any questions about this transmittal, Contact Loran Shamis at loran.shamis@tucsonaz.gov

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised development package
TW New Development Review REVIEW COMPLETED CIP-0824-00025 • CIP - Commercial Structure - Initial v1 • 300 S FIRE CENTRAL PL

1. Tucson Water’s NW131413 valve map shows there are public water mains on this property. Please see this valve map to see where the existing public water mains are located in this area. Copies of the valve map(s) and ‘as-built’ plans referenced in these comments may be obtained from Tucson Water’s Mapping & GIS Center by sending an e-mail request for them to TWMapInfo@tucsonaz.gov.

2. I found no sheet in these plans that show the routing of the proposed new underground electric lines to and from the proposed ETR Utility Padmount Transform shown by Keynote 1 on Sheet E0.2 and their spatial relationship to the the existing underground utilities on the site. I would think such sheet is needed to demonstrate there will be no conflicts between these features.

3. The New Development Section has no developer financed projects in this area that may affect or be affected by this Capital Improvement Project.

4. No further reviews by Tucson Water’s New Development Section is required, as no construction of new public water mains, or relocation of existing public water mains is proposed as part of this project.


Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
TW Planning and Engineering Review REVIEW COMPLETED North arrow on sheet 4 (E0.2) is 90° off.
Please show underground utilities including water. There is an existing 8" PVC line near the referenced transformer.
If the electrical feeds have water crossings - please indicate.
Water - PDSD REVIEW COMPLETED
Zoning Modifications - DDO REVIEW COMPLETED
Zoning Modifications - IPP REVIEW COMPLETED
Zoning Modifications - MS&R REVIEW COMPLETED
Zoning Modifications - Variance REVIEW COMPLETED