Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Requires Resubmit
Review Details: CIP - DEVELOPMENT SITE - INTERIM v.1
Plan Number - CIP-0725-00016
Review Name: CIP - DEVELOPMENT SITE - INTERIM v.1
Review Status: Requires Resubmit
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| Real Estate | NOT REQUIRED | PLease contact the Real Estate Division if any property rights need to be addressed. | |||
| Zoning Administration | NOT REQUIRED | ||||
| External Reviewers - Tucson Electric Power (TEP) | REQUIRES RESUBMIT | October 28, 2025 WO#T164437 City of Tucson Planning and Development Services Attn: CDRC Admin Team Dear CDRC Admin Team Subject: Dell Urich Golf Course and 22nd Street CIP-0725-00016 Tucson Electric Power Company (TEP) has reviewed and cannot approve the development plan submitted 9/24/2025. There are no existing facilities within the development. Further: Underground line and TEP Easements not shown on Development Plan. Enclosed is a copy of a TEP facilities map showing the approximate location of the existing facilities. Any relocation costs will be billable to the customer. To apply for electric service, please call the New Construction department at (520) 918- 8300. Please submit a final set of plans including approved site, electric load, paving off-site improvements and irrigation plans. If available, include a PDF version of the plans. If easements are required, they will be secured by separate instrument. Should you have any easement questions, please contact our Land Resources Department, LandReviews@tep.com. Should you have any technical questions, please contact the area designer, Martin Salazar (520) 305-6713 msalazar@tep.com Sincerely, Design Admins Design Admins Tucson Electric Power |
|||
| Historic | REQUIRES RESUBMIT | Historic review completed. Project has a federal nexus and will require full Section 106 compliance. A "Request for Cultural Clearance Form" should be filled out and submitted to the PDSDHistoric@tucsonaz.gov. The HPO will determine the scope of cultural resources work needed to be in legal compliance. | |||
| TW Planning and Engineering Review | REQUIRES RESUBMIT | Please move or relocate the retention basin at station 1+70 as this has a chance of compromising the side cover for the 30in CCP. Please provide pothole information at the intervals where the MUP lies over the 30in CCP (requested by Engineering Manager K. Miller). The irrigation detail for trenching for 4 inch pipe has a detail (sheet 48) that specifies a depth of 33 inches. Please revise 4 inch irrigation sleeves at locations where trenching compromises the minimum 44in of cover for the 30in CCP. Disturbing and then recompacting the cover for the now 73 year old concrete may have adverse effects. Also, the Irrigation section of the the plan set still shows trees and shrubs to be planted on or within 10 feet of the 30in CCP water main. Please refer to my note on the 60% plans for comments on "root-balls" and their proximity to water mains. Please email me at Michael.asbury@tucsonaz.gov with any questions |
|||
| CDRC Post Review Express | REVIEW COMPLETED | Please address reviewers' comments for the next submittal. Thanks If any of the following apply, a Fugitive Dust Activity Permit is required from the Pima County Department of Environmental Quality (PDEQ). Earthmoving or Land Clearing over 1 acre Trenching over 300 feet for utility installation or repair Road construction over 50 feet Blasting Please contact the following to obtain your permit. Fugitive Dust Activity Permit: Contact Pima County ADEQ at (520) 724-7400 https://www.pima.gov/596/Fugitive-Dust Once received you may upload your permit to the attachment section along with any external reviewer approval letters. If you have any questions regarding this information, please contact Sonya Bermudez at sonya.bermudez@tucsonaz.gov or 520-730-7979. |
|||
| External Reviewers - Arizona Department of Transportation (ADOT) | REVIEW COMPLETED | Good Afternoon, ADOT has no comments on this CIP. Thank you for the opportunity to review. |
|||
| External Reviewers - COT Parks & Recreation | REVIEW COMPLETED | Approved Regarding CIP-0725-00016, The City of Tucson Parks and Recreation Department has no additional requirements for the Project and no further reviews by TPRD are required. Description: Plans for Dell Urich Golf Course and 22nd Street Multi-Use Path Improvements Parcel: 12620001C Regards, Joe Barr Project Manager Tucson Parks and Recreation |
|||
| External Reviewers - Pima Association of Governments | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | |||
| External Reviewers - Southwest Gas | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | |||
| External Reviewers - United States Postal Service (USPS) | REVIEW COMPLETED | CDRC sent FYI email sent to PAG, USPS, SWG. No further action is required. | |||
| New Services/JOC | REVIEW COMPLETED | Tucson Water – New Area Development has no objection to the proposed work for CIP-0725-00016, provided all existing and proposed irrigation associated with the path improvements is connected to the reclaimed water system surrounding the park. For reclaimed water line locations, refer to valve map NE161414. For any questions, contact Mario Rivera Alvarez at mario.riveraalvarez3@tucsonaz.gov | |||
| ROW Engineering Review | REVIEW COMPLETED | ||||
| Site Engineering | REVIEW COMPLETED | Permit: CIP-0725-00016 Location: 600 S ALVERNON WY Review Date: 10/6/2025 Site Engineering Comments: 1. In reference to general note #18 – delineate and call out the protected riparian areas on the site plans. If you have any questions or concerns, please contact Marco Contreras Marco.contreras@tucsonaz.gov |
|||
| Site Landscape | REVIEW COMPLETED | ||||
| Site Zoning | REVIEW COMPLETED | FROM: Ramiro Olivarez PDSD Zoning Review Section PROJECT: CIP-0725-00016 600 S ALVERNON WY TUCSON, AZ 85711 Dell Urich Golf Course (2nd Review) (CIP Intermediate Review) TRANSMITTAL DATE: October 21, 2025 COMMENTS: Resubmit revised drawings along with a detailed response letter, which states how all Zoning Review Section comments were addressed. 1. Previous Comment 1: Upon formal submittal provide the development package (DP) case number adjacent to the title block on each sheet. Follow up to previous comment 1: Previous comment 1 will remain for a reminder to add upon formal DP submittal. 2. Comment: Add a note under the general, zoning and land use notes listing the height of proposed fence. 3. Previous Comment 3: Draw, label, and dimension all applicable building setback lines, future right-of-way building setback lines and setback lines such as erosion hazard, floodplain detention/retention basins, and zoning, including sight visibility triangles, will be shown. **Follow up to comment 3: Draw, label, and dimension the street setback line from 22nd Street. Add a note under the general, zoning and land use notes the minimum required street perimeter yard is ten feet. UDC 6.4.5.C.2.a, “For nonresidential and multifamily development abutting an Arterial or Collector Street the minimum required street perimeter yard is ten feet, as measured from the existing or future property line as determined by the adopted Major Streets and Routes Plan, whichever is greater.” 4. Previous Comment 4: Show on-site pedestrian circulation and refuge utilizing location and the design criteria in Section 7-01.0.0, Pedestrian Access, of the Technical Standards Manual. On all site sheets clearly dimension the width of all proposed path improvements. Follow up to comment 4: Clarify the width of the new path. Is the width 7 ft or 12 ft in width? 5. Comment: Under the general, zoning and land use notes number 4 remove the first bullet point ‘RECREATION – LAND USE GROUP: PARKS AND RECREATION; LAND USE CLASS: USE SPECIFIC STANDARDS PER UDC 4.9.13 B & C” 6. Comment: Additional comments may be forthcoming on the next review based on the proposed use. RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Corrected CIP development package. If you have any questions about this transmittal, please contact Ramiro.Olivarez@tucsonaz.gov |
|||
| Storm to Shade Review | REVIEW COMPLETED | ||||
| Urban Forestry | REVIEW COMPLETED | ||||
| Water - PDSD | REVIEW COMPLETED | ||||
| Zoning Administration | REVIEW COMPLETED |